OPERATIONAL CONTROLS 
  

The AT Series dimmer provides a user interface on the circuit board and connection points for switches to activate 
scenes that can be preset into the AT series dimmer. This is also the connection point for the DMX control wires.

 

 
 

 

 

INITIAL SET UP 

 

Set up of the AT Series dimmer is done using the 2 LED indicators and the 3 push buttons located at the bottom 
left of the low voltage section of the circuit board inside of the unit.  Use these controls to set the unit to operate 
correctly for the type of input power being applied to the unit.   

 

Set  the  Input  Power  Phase  for  each  dimmer  channel.  This  must  be  set  correctly  or  dimmers  will  not  operate 
correctly.  

 

Symbol 

Function 

Value 

P2 

Ch. 2 Input Phase 

A, B, or C 

P3 

Ch. 3 Input Phase 

A, B, or C 

P4 

Ch. 4 Input Phase 

A, B, or C 

 

For P2-P4, set to A, B, or C depending on which phase each channel gets its power from.  For single phase power 
set P2, P3, and P4 to "A". 

Summary of Contents for AT SERIES

Page 1: ...applications It can be supplied with up to four 2400 Watt lighting circuits channels and be remotely controlled by a DMX lighting console The AT series dimmers are provided with a fast acting 20 Amp...

Page 2: ...Standard sized knockout holes are provided in the top bottom and right side of the chassis for wiring Be sure that the vent holes in the chassis and cover are not obstructed since they are needed for...

Page 3: ...up of the AT Series dimmer is done using the 2 LED indicators and the 3 push buttons located at the bottom left of the low voltage section of the circuit board inside of the unit Use these controls t...

Page 4: ...abeled on the unit If a circuit breaker will not remain closed then there is an overload at the lamps for that channel which MUST be corrected before operation can continue INDICATORS There is an LED...

Page 5: ...hting is controlled by external momentary switch closures either manually or by automated equipment The AT 402 dimmer is designed to activate preset lighting conditions in response to these controls A...

Page 6: ...tched channel controls and DMX input It sets all channels to maximum intensity and remains in effect until the button is pushed again At that time the unit will Resume normal operation return to the i...

Page 7: ...n the SYMBOL channel preset level and preset fade and its VALUE intensity and fade time There are 2 digits and 3 buttons to control everything Press the NEXT button to advance through each SYMBOL Pres...

Page 8: ...nnel 2 Preset D up fade time 1 99 seconds d2 Channel 2 Preset D down fade time 1 99 seconds A3 Channel 3 Preset A up fade time 1 99 seconds A3 Channel 3 Preset A down fade time 1 99 seconds b3 Channel...

Page 9: ...from feed circuits before changing the fuse Service by other than the manufacturers authorized agents may void your warranty The best way to prolong the life of your unit is to keep it cool clean and...

Page 10: ...rves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and wi...

Reviews: