background image

VP PARABOLIC

VPA2G29PR232

Page 2 of 2

2'x4' RECESSED FLUORESCENT, 4" DEEP, 18 CELL (2x9) PARABOLIC LOUVER

STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)

Lightolier 

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902

SECTION 2/Folio G05-26  REV. A

Job Information

Type:

OPTIONS & ACCESSORIES

PLASTER FRAME:

Catalog Number: 

PF24

.

CONTINUOUS ROW INSTALLATION: 

For F type fixtures, half-width flanges are

required between fixtures, Order Catalog Number: 

S2FCTRIM

(each joint).

SPLAY TRIM:

For T ceiling type only. SUFFIX: 

CTZ24 S2  SPLAY TRIM

.

RADIO INTERFERENCE FILTER: 

120 or 277 volt, 50 or 60 Hz. One per fixture

standard. SUFFIX: 

RF

.

ELECTRICAL/WIRING OPTIONS: 

Consult factory.

AIR CLOSURE STRIP:

SUFFIX 

ACS4

(factory installed). 

DRYWALL KIT:

Order Catalog Number: 

FK92X4

. Request Folio OA30-10.

CHICAGO PLENUM:

SUFFIX: 

CP

.

SPECIFICATIONS

PERFORMANCE:

In an installation of 2 lamp 32W luminaires in a room cavity

ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .76 with a spacing to mounting ratio of 1.8 perpendicular to the lamps. To
meet IES RP1 preferred requirements for VDT areas the VCP (visual comfort proba-
bility) shall not be less than 93 either crosswise or lengthwise and the maximum
average brightness at 55°, 65°, 75° and 85° shall not exceed 834, 0, 0 and 0 can-
delas per square meter respectively in the 0°, 45°, and 90° horizontal planes.
Candelas at Nadir (0°) not to exceed 1437.  

SPECIFICATIONS (continued)

AIR HANDLING:

(VPA only) side air passages for air supply or air return.

Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends. 

MATERIALS: Chassis parts 

are die formed code gauge cold rolled steel.

Housing

side rails hemmed over and housing ends turned-in for safe handling.

Louver

is pre-anodized aluminum (Coilzak® or equal).

FINISH: Chassis exterior

–black baked polyester enamel. 

Cavity

–white baked

polyester enamel minimum 86% reflectance. Phosphate undercoating.

Louver

–low iridescence specular anodized vertical grain aluminum reflector

sheet is standard.

ELECTRICAL:

Thermally protected class “P” ballast C.B.M. approved, non PCB.

If K.O. is within 3" of ballast, use wire suitable for at least 90°.

LABELS:

I.B.E.W./UL and C-UL.

PHOTOMETRY

MODEL NO. VPA2G29PR232SO

coefficients of utilization — zonal cavity method  

(effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

78

76

74

72

70

69

69

68

67

2

73

69

65

65

63

60

63

61

59

3

68

62

58

59

56

53

58

55

52

4

63

56

51

54

50

47

52

49

46

5

59

51

46

49

45

41

48

44

41

6

54

46

41

45

40

37

44

40

36

7

51

42

37

41

36

33

40

36

33

8

47

39

33

37

33

29

36

32

29

9

44

35

30

34

30

26

34

29

26

10

41

33

27

32

27

24

31

27

24

visual comfort probability 

(rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

92

95

95

87

94

94

92

85

20

30

92

95

95

87

94

94

93

88

20

40

93

95

95

88

95

94

93

88

20

60

93

95

95

88

95

94

93

88

30

20

92

95

95

89

94

94

93

87

30

30

93

95

96

89

95

94

93

89

30

40

93

95

96

89

95

94

93

89

30

60

93

95

96

89

95

94

93

90

30

80

93

95

96

90

95

94

93

90

40

20

92

95

95

91

94

94

93

88

40

30

93

95

96

91

95

94

93

89

40

40

93

95

96

91

95

94

93

90

40

60

93

95

96

91

95

94

93

90

40

80

93

95

96

91

95

94

93

90

40

100

93

96

96

91

95

94

93

90

60

30

93

95

96

91

95

94

93

89

60

40

93

95

96

91

95

94

93

90

60

60

93

96

96

91

95

94

93

90

60

80

93

96

96

91

95

94

93

90

60

100

93

96

95

91

95

94

93

90

100

40

93

95

96

91

95

94

93

90

100

60

93

96

95

91

95

94

93

90

100

80

93

96

95

91

95

94

94

90

100

100

93

96

95

91

95

94

94

90

room cavity ratio

luminaries lengthwise

luminaries crosswise

ORDERING INFORMATION

Explanation of Catalog Number.   Example: VPA2G29PR232120SOGLR

LER = FP - 63.8

IW - 61.2

BF - 96.2

Comparative yearly lighting energy cost per 1000 lumens = $3.76

VP

VP:

4" Deep

Pre-anodized

Aluminum

Louver

For Intense

VDT Use

A

BODY STYLE:

A=

Air Handling

S

=Static

2

FIXTURE

WIDTH

CEILING TYPE:

G

=Grid

(lay-in T bar)

F

=Flanged

(overlap)
Z spline and
plaster frame

T

=Slot grid or       

two-directional
concealed T
(see options)

29

NUMBER OF

CELLS:

(2 rows of

9 cells)

P

LOUVER

FINISH*:

P

=Low

Iridescence
Specular

R

PREMIUM

SPECULAR

REFLECTOR

2

LAMP

QUANTITY

LAMP TYPE/

FIXTURE

LENGTH:

32

=T8

34

=T12

(Nominal 48")

VOLTAGE:

120 or 277

OPTIONS:

Add appropriate
suffix to catalog

no, ie: (

GLR

)

BALLAST TYPE:

1-2 Lamp Mag. T12

LE

<

20THD

<

10THD

1-2 Lamp Elec. T8

SO*

H

I

*

LOL T8 Dimming

PS

*

Instant Start Standard

Other dimming options consult factory.

Reviews: