background image

Skyway

SKS2GPK232 or 332

Page 2 of 2

2' x 4' Recessed Fluorescent, Tri-Lens Frame

Static or Air Supply/Return, 2 or 3 Lamp T8

Ordering Information

Explanation of Catalog Number. Example: SKS2GPK232UNVHI

Options/Accessories

Fusing:

Internal fast blow fusing: SUFFIX:

A

.

Internal slow blow fusing: SUFFIX:

C

.

Drywall Kit:

Order Catalog Number:

FK92X4

.

Electrical Wiring Options:

Consult factory.

For motion or light sensor:

See Folio OA20-10 and OA20-30.

Specifications

Performance:

In an installation of 2 lamp 32W luminaires in a room cavity ratio of 1,

with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80.
To reduce glare the average brightness at 65° shall not exceed 1511 candelas per
square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall
not be less than 67.1%.

Air Handling: (SKA only)

side air passages for air supply or air return. Supply air is

discharged vertically. Optional side closure strips. Air return is also provided through the
lamp compartment through fixture body ends.

Materials

:

Chassis parts

are die-formed code gauge cold rolled steel. Housing has side rails

hemmed over and housing ends turned-in for safe handling.

Specifications (continuned)

Finish

:

Chassis exterior

–black baked polyester enamel.

Cavity

–white baked poly-

ester enamel minimum 86% reflectance. Rust preventative undercoating.

Reflectors-

95% reflective white powder coated.

Lens:

Proprietary high quailty frost white acrylic and clear conical prism lens assembly.

Electrical:

Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is

within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.

Labels:

I.B.E.W./UL and ULc Listed.

This product may have a mercury containing lamp. Manage in accord with Disposal
Laws. See: www.lamprecycle.org

Options:

Add appropriate suffix

to catalog no., ie: (A)

Skyway

Recessed

Fluorescent

Body Style:

S

= Static

A

= Air

2

Fixture

Width

Ceiling Type:

G

= Standard

Grid

T

= Slot Grid

P

Side Lens:

P

= Frost White

Acrylic Lens

32

K

Center Lens:
K

= Pattern 19

.156 Virgin

Acyrlic Lens

Lamp

Quantity

2

=2 Lamp

3

=3 Lamps

0.0

45.0

90.0

FLUX

0

1990

1990

1990

5

1972

1975

1978

188

15

1875

1891

1913

535

25

1702

1765

1831

815

35

1464

1589

1647

979

45

1156

114

1063

867

55

732

714

643

630

65

406

401

354

400

75

205

185

170

207

85

48

35

31

46

90

0

0

0

Model No. SKS2GPK232UNVC5

LER = FP - 69.3

IW - 51.9

BF - 0.77

Comparative yearly lighting energy cost per

1000 lumens = $3.46

Report Number: G2008169
Catalog Number: SKS2GPK232UNVC5
Lamps: (2) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture

prismatic acrylic lens assembly.

Ballast: INC-2P32-LW-SC
Report is based on 3100 Lumens per lamp.

Efficiency: 75.3%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

45.600

21.600

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

2572.

2478.

2365.

55

2008.

1958.

1764.

65

1511.

1493.

1318.

75

1246.

1124.

1033.

85

866.

632.

560.

LUMINANCE DATA IN CANDELA/SQ. METER

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 83 80 77 75 73 71 72 70 69

0

2 76 70 66 66 63 60 64 61 58

0

3 70 63 57 59 55 51 57 54 50

0

4 64 56 50 53 48 44 52 47 44

0

5 60 51 44 48 43 39 47 42 39

0

6 55 46 39 44 38 34 43 38 34

0

7 51 42 35 40 35 31 39 34 31

0

8 48 38 32 37 31 28 36 31 28

0

9 45 35 29 34 29 25 33 28 25

10 42 33 27 31 26 23 31 26 23

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

1537

24.8

32.9

0

0-

0

40

2516

40.6

53.9

0

0-

0

60

4013

64.7

86.0

0

0-

0

90

4666

75.3

100.0

90-180

000

0

0.0

00

0.0

0

0-180

4666

75.3

100.0

ZONAL LUMEN SUMMARY

Voltage:

120, 277 or

UNV

=120-277

0.0

45.0

90.0

FLUX

0

3104

3104

3104

5

3082

3082

3092

293

15

2940

2945

2951

831

25

2672

2662

2625

1222

35

2284

2184

2158

1382

45

1710

1657

1665

1284

55

1052

1099

990

955

65

608

639

565

626

75

323

296

284

333

85

90

74

66

88

90

15

16

8

Model No. SKS2GPK332UNVH3

LER = FP - 70.9

IW - 87.0

BF - 0.88

Comparative yearly lighting energy cost per

1000 lumens = $3.38

Report Number: G2008332
Catalog Number: SKS2GPK332UNVH3
Lamps: (3) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture

prismatic acrylic lens assembly.

Ballast: ICN-3P32-SC
Report is based on 3100 Lumens per lamp.

Efficiency: 75.4%

CIE Type-Direct-Indirect
Plane:

0-Deg

90-Deg

Spacing Criteria:

1.2

1.3

Shielding Angles:

90

90

Plane:

0-Deg

90-Deg

Luminous Length:

45.600

21.600

CANDELA DISTRIBUTION

AVERAGE AVERAGE AVERAGE AVERAGE

IN DEG.

0-DEG.

45-DEG.

90-DEG.

45

3804.

3686.

3704.

55

2885.

3014.

2715.

65

2263.

2379.

2103.

75

1963.

1895.

1726.

85

1624.

1336.

1191.

LUMINANCE DATA IN CANDELA/SQ. METER

ZONE

LUMENS % LAMP

% FIXT

0

0-

0

30

2346

25.2

33.5

0

0-

0

40

3728

40.1

53.2

0

0-

0

60

5967

64.2

85.1

0

0-

0

90

7014

75.4

100.0

90-180

000

0

0.0

00

0.0

0

0-180

7014

75.4

100.0

ZONAL LUMEN SUMMARY

SK

Standard Skyway

SY

For NYC Code – I.B.E.W. Manufactured

Lamp:

(By Others)

32

=T8 32W

(Nominal 48")

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20

0

RC

80

50

30

RW 70 50 30 50 30 10 50 30 10

0

1 83 80 77 75 73 71 72 70 68

0

2 76 70 66 66 63 60 64 61 58

0

3 70 63 57 59 55 51 57 53 50

0

4 64 56 50 53 48 44 51 47 44

0

5 60 50 44 48 43 39 47 42 38

0

6 55 46 39 44 38 34 42 38 34

0

7 51 42 35 40 35 31 39 34 30

0

8 48 38 32 37 31 28 36 31 28

0

9 45 35 29 34 29 25 33 28 25

10 42 33 27 31 26 23 31 26 23

Ballast Type:

Ballast

<

20THD

<

10THD

Factor

1 or 2 Lamp Elec. T8

SO*

H

I

*

0.88

1-3 Lamp Elec. T8

O3*

H3*

0.88

Advance Optanium

1 or 2 Lamp Elec. T8

C5*

0.77

1 - 3 Lamp Elec. T8

C6*

0.77

LOL Dimming T8

PS

*

*Instant Start Standard
Other dimming options. Consult factory.

NOTE:

For

T8 UNV

, you must use

H

I

OR

H3

Ballast Code.

Job Information

Type:

For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595

08/10

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © Philips Group

Section 5/Folio MA12-18 Rev. B

Reviews: