background image

Lighting Systems

 

Baselyte-BSL16

Page  of 8   

3 Light T5 HO Semi-Indirect

Job Information 

Type:

 
Job Name: 
Cat. No.: 

 

Lamp(s): 
Notes: 

Lightolier 

a Genlyte Company 

www.lightolier.com

63 Airport Road, Fall River, MA 02720 • (508) 679-83 • Fax (508) 674-470

We reserve the right to change details of design, materials and finish.

© 2005 Genlyte Group LLC • 0205 Rev.

Ordering Information

Family

H

 = T5 HO

5

 = Semi-Indirect

03

LN           

H

5

BSL

03 

= 3 Light

LN

 = Perforated

04

 = 4’

08

 = 8’

12

 = 2’

C

 = Custom Color

W

 = Standard

 

  White

Distribution

Lamp Type

No. of Lamps

Housing

Module Length

Wiring 

Voltage

Ballast

Finish

Weight = 3.0 lb./ft

= Standard  

<0% THD

= Standard  

<0% THD  
w/fusing 

1

 = cct.

2

 = 2cct. 

= cct. w/EC/NL

= 2cct. w/EC/NL

5

 = cct. w/EM Battery

6

 = 2cct. w/EM Battery

7

 = cct. w/Dimming

= cct. w/cct.  

Thru wire

9

 = 2cct. w/cct.  

Thru wire

Note:

 Please consult 

wiring section of spec
sheets for more
wiring options.

Specifications

Features

.  Housing: die-formed 20ga. cold rolled steel
2.  End Set: die-cast metal with baked powder coat finish
3.  Lamping: three T5 HO lamps
4.  Configuration: 4’, 8’ and 2’ module lengths or continuous rows
5.  Ballasts: electronic 20V or 277V

Finish

High-quality white powder coat with textured matte finish.
Custom colors available. Consult factory.

Mounting

Aircraft cable gripper is tamper-resistant and provides infinite vertical
adjustment capability. Aircraft cable, crimp and cable gripper independently
tested to meet stringent safety requirements. 

Electrical

All luminaires are factory pre-wired to module ends with quick-wire 
connectors.

Joints & Intersections

Self-aligning joining system with hands-free pre-joining wire access.

Labels

UL, CSA standards.

Individual Fixtures

.  Determine the number of individual modules required
2.  Order one end set per module
3.  Order one non-power mount per module
4.  Order one power mount per module

Continuous Rows*

.  Determine run length
2.  Order the appropriate number and length of modules for complete run 
3.  Order one end set for each run
4.  Order one non-power mount for each module
5.  Order one power mount per run
6.  Order one joiner per module minus one (e.g. 3 modules requires 2 joiners)

*Note

: Some runs may require additional power mounts. Please see the  

‘Run Configuration’ table on the next page for more details.

Ordering Instructions

D

 = Dual 20V   

& 277V 

1

 = 20V

2

 = 277V 

Note:

 Option‘D’ is

standard. Voltage
options  and 2 are
only available with
EM Battery and 
Dimming wiring
options.

angled lamp

Summary of Contents for Lighting Systems Baselyte-BSL16

Page 1: ...r 277V Finish High quality white powder coat with textured matte finish Custom colors available Consult factory Mounting Aircraft cable gripper is tamper resistant and provides infinite vertical adjus...

Page 2: ...1 58 81 99 107 45 64 75 94 111 118 35 88 92 109 119 125 25 109 110 120 127 131 15 123 123 126 131 133 5 131 131 131 131 131 0 132 132 132 132 132 COEFFICIENTS OF UTILIZATION EFFECTIVE CEILING CAVITY R...

Page 3: ...anded aircraft cable Supported by T bar and secured to structure J Box 4 square supplied by others Fully adjustable vertically at fixture 65 lbs maximum load Canopy Diameter of 3 3 4 x 7 32 Cable 7x7...

Page 4: ...ength 1 Power Mount 2 4 8 12 3 Conductor BSLM3102P13 BSLM3104P13 BSLM3108P13 BSLM3112P13 4 Conductor BSLM3102P14 BSLM3104P14 BSLM3108P14 BSLM3112P14 7 Conductor BSLM3102P17 BSLM3104P17 BSLM3108P17 BSL...

Page 5: ...ctor BSLM1102P23 BSLM1104P23 BSLM1108P23 BSLM1112P23 Non Power Mount BSLM1102N BSLM1104N BSLM1108N BSLM1112N Meets UBC OSHPD and DSA seismic requirements Canopy Diameter of 5 1 4 x 3 4 power Cable 7x7...

Page 6: ...M Bodine standard LP550 Type E Chloride high performance CTP1300 Type P Bodine high performance LP600 All lamps wired on one circuit plus a battery pack is wired to one lamp A hot lead is connected t...

Page 7: ...witching with Emergency Circuit Night Light EC NL One 4 section in two circuit fixture center outer switching to be wired on a separate thru circuit Leads for both normal circuit and EC NL circuit wir...

Page 8: ...red for A B switching in alternate 4 sections 2 Circuit A B Switching alternate 4 sections Type B 2cct Type A 2cct w 1cct thru wire Type S 2cct w 2cct thru wire 2 Circuit A B Switching alternate 4 sec...

Reviews: