background image

9 1/2" Dia.

* 6 3/4" min. is for
 up to 3/4" thick ceiling.

7

2

3

1

6

8

5

1 1/4" Max. Ceiling Thk.

7 1/4" MAX.

6 3/4" MIN.* 6"

Adjustment 
(mounting 
bars included)

13 3/4" to 24" 

4

7 3/4"

15 3/4"

Ceiling Cutout: 6 11/16" Dia.

Frame-In Kit 

Reflector Trim

C6ALV

 

Adjustable Accent

 

C6P36A

 

35W - 75W PAR36 (12V)

 

25W PAR36 (5.5V)

 

35W - 75W AR111 (12V)

Calculite

®

 Evolution Recessed Downlighting 

C6ALV

Page 1 of 1 

6" Aperture PAR36 Low Voltage Non-IC AirSeal

®

 Frame-In Kit

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

 

Lightolier 

a Genlyte Thomas Company 

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Thomas Group LLC (Lightolier Division) • B0711

Features

1.  Housing: Steel, 0.03" (22 ga.). Top Cover: Aluminum, 0.04" (14 ga.). Matte 

black finish. AirSeal

®

 housing minimizes air leakage to less than 2CFM at 

1.57 PSF (or 75pa).

2.  Mounting Frame: 

Die-cast aluminum for dry or plaster ceilings. Locks into 

position along length of mounting bars with locking screws.

3.  Retaining Springs: 

Precision-tooled steel springs secure reflector trim to 

mounting frame for quick, tool-less installation.

4.  Mounting Bars: 

Galvanized steel, 0.06" (16 ga.). Bars pivot for easy instal-

lation and wire-in below ceiling line. Bars extend to accommodate 16" to 24" 
O.C. joist spacing. Bars can accommodate 12" O.C. joist spacing after a slight 
field modification (see instruction sheet). Integral self-tapping screws for 
securing to wood or metal construction. Built-in tabs for locking to T-bars 
without the need of accessories. 

5. Transformer: 

Magnetic, 120V/277V dual tap primary, nominal 12V and 5.5V 

secondary.

6.  Snap-In Connectors: 

Keyed to accept power and socket harnesses which 

are provided with reflector trim.

7.  Junction Box: 

Galvanized steel .063" (14 ga.). UL listed for maximum of 8 

No. 12 AWG 90°C through branch circuit conductors. Accessible from inside 
and outside of fixture. Outside J-Box door is hinged for maximum opening. 
Snap-in plug is provided on inside cover for quick connection to power har-
ness.

8.  Thermal Protector: 

Meets NEC and UL requirements. Insulation must be 

kept 3" away from fixture sides and wiring compartments and must not be 
placed above fixture in a manner which will entrap heat.

9.  Reflector Trim: 

Compatible reflector trims are listed above. See separate 

reflector trim specification sheets for complete catalog numbers and details.

Options & Accessories

Chicago Plenum

 

Consult Factory

Labels

UL Listed (suitable for damp locations), I.B.E.W. 
Air leakage is less than 2cfm at 75pa, tested in accordance with ASTM E-283.

Reviews: