9 1/2" Dia.
* 6 3/4" min. is for
up to 3/4" thick ceiling.
7
2
3
1
6
8
5
1 1/4" Max. Ceiling Thk.
7 1/4" MAX.
6 3/4" MIN.* 6"
Adjustment
(mounting
bars included)
13 3/4" to 24"
4
7 3/4"
15 3/4"
Ceiling Cutout: 6 11/16" Dia.
Frame-In Kit
Reflector Trim
C6ALV
Adjustable Accent
C6P36A
35W - 75W PAR36 (12V)
25W PAR36 (5.5V)
35W - 75W AR111 (12V)
Calculite
®
Evolution Recessed Downlighting
C6ALV
Page 1 of 1
6" Aperture PAR36 Low Voltage Non-IC AirSeal
®
Frame-In Kit
Job Information
Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier
a Genlyte Thomas Company
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2011 Genlyte Thomas Group LLC (Lightolier Division) • B0711
Features
1. Housing: Steel, 0.03" (22 ga.). Top Cover: Aluminum, 0.04" (14 ga.). Matte
black finish. AirSeal
®
housing minimizes air leakage to less than 2CFM at
1.57 PSF (or 75pa).
2. Mounting Frame:
Die-cast aluminum for dry or plaster ceilings. Locks into
position along length of mounting bars with locking screws.
3. Retaining Springs:
Precision-tooled steel springs secure reflector trim to
mounting frame for quick, tool-less installation.
4. Mounting Bars:
Galvanized steel, 0.06" (16 ga.). Bars pivot for easy instal-
lation and wire-in below ceiling line. Bars extend to accommodate 16" to 24"
O.C. joist spacing. Bars can accommodate 12" O.C. joist spacing after a slight
field modification (see instruction sheet). Integral self-tapping screws for
securing to wood or metal construction. Built-in tabs for locking to T-bars
without the need of accessories.
5. Transformer:
Magnetic, 120V/277V dual tap primary, nominal 12V and 5.5V
secondary.
6. Snap-In Connectors:
Keyed to accept power and socket harnesses which
are provided with reflector trim.
7. Junction Box:
Galvanized steel .063" (14 ga.). UL listed for maximum of 8
No. 12 AWG 90°C through branch circuit conductors. Accessible from inside
and outside of fixture. Outside J-Box door is hinged for maximum opening.
Snap-in plug is provided on inside cover for quick connection to power har-
ness.
8. Thermal Protector:
Meets NEC and UL requirements. Insulation must be
kept 3" away from fixture sides and wiring compartments and must not be
placed above fixture in a manner which will entrap heat.
9. Reflector Trim:
Compatible reflector trims are listed above. See separate
reflector trim specification sheets for complete catalog numbers and details.
Options & Accessories
Chicago Plenum
Consult Factory
Labels
UL Listed (suitable for damp locations), I.B.E.W.
Air leakage is less than 2cfm at 75pa, tested in accordance with ASTM E-283.