Document 36 II LWS-MKIII, pub V5 © Copyright 2012 LPI
Page
37
After automatically restarting, the Console will have regained the following default values:
• Alarm Duration: 10secs.
• All Clear Timeout Period: 15.mins
• All Clear Mode: Normal
• Console IP Address: 19.2.168.1.9.0
• Console IP Mask: 25.5..25.5..25.5..0
• Gateway Address: 0.0.0.0
• DNS Address: 0.0.0.0
• Alarm Enable On Time : 07.:30:00
• Alarm Enable Off Time : 18:30:00
• Username : admin
• Password : admin
Power
Cord
Relay Contacts
(optional)
Power On LED
Ethernet Cable
LWS Console
Ethernet Port
Restore Defaults
Coaxial
Antenna Cable
Restoring Console Factory Default Values
Before restoring the LWS to factory default settings you should try to ensure that the LWS console, the
Sensor and all the range extenders are communicating.
To restore the LWS to factory default values, use a paper clip or similar object to press the factory
default reset button.
When the button is pressed the red “Power On” led will initially turn off. Keep the button pressed until
the led starts flashing, this will take 3 seconds. The LWS will now reboot with the default settings.
If the button is released before the Power On LED starts flashing the LWS will do nothing.
Note: After restoring the factory defaults, the
Console IP Address settings will need to be
changed to allow connectivity to a connected
computer, or via a local network. Also please
set all values manually to your required
settings.