ENGLISH
Status and Information
Menu
Submenu
Function
Stepper info
1-10
Pre-programmed scenes 1 to 10
Error Logging
Error Logging
12
:
:03
Hall error
Hallo short
Opti error
Lose stop
Hit
Lamp error
NTC error
Fan error
Display of detected errors after power-on
Display of time of the power failure if the error
occurs (in minutes)
The effective Hall signal is not detected when
motor is reset.
When the motor is reset, the motor's Hall
signal is always effective.
When the motor is reset, no effective
optocoupler signal is detected.
Motor does not run during operation
No positioning after motor reset
Lights defective
The temperature sensor signal is not correct.
The main fan is not working properly.
Fixture status
Communication
prec
Error cnt
Light Temperature
Panel
Temperature
Sensor1
Temperature
Indication of internal connection error
Display of the faulty frames after switching on
and the total number of faulty frames
LED temperature display
Display temperature or ambient temperature
Display indoor temperature
Version
Device
Model
Panel Display
Main Board
The name of the device is the same as the
device information of RDM.
The name of the device is the same as the
device information of RDM.
Firmware Version and Display serial number
Firmware Version and serial number Main
Board
Light time
000-255
This function can be used to read out the
temporary operating hours of the device since
it was switched on.
Total time
000-255
With this function the operating hours of the
device can be read out.