Lighting Technologies SKYLINE LED/M Manual Download Page 2

 

SKYLINE LED 

  

  

 

 

 

 

Name 

 

Code 

 

Rated 

power, 

W  

Luminou

efficienc

y, lm/W  

Luminous 

flux, lm 

 
 

Weight, kg 

 

 

 
 

CRI, Ra 

Size, mm, 

AxBxC 

 

SKYLINE LED 30 DK 4000K /M/ 

1707000420 

35 

124 

4350 

12,7 

>80 

 

 

 

730x490x130

 

SKYLINE LED 60 DW 4000K /M/ 

1707000430 

52 

148 

7700 

 

 

14,7 

>70 

SKYLINE LED 90 DW 4000K /M/ 

1997031940

 

 

90 

133 

12000 

>70 

SKYLINE LED 120 DW 4000K /M/ 

1997031950

 

 

 

104  

137 

14200 

>70 

 

Notes

:  

-  **CCT 

– correlated color temperature.  

Rated power consumption tolerance ±10%. 

- Nominal values of luminous flux, weight 

tolerance is ±10%. 

Rated CCT tolerance ±300К. 

- The supply mains must be protected from communication and electric impulse noise. 

The main characteristics of line voltages at a network user’s supply terminals in public AC electricity networks 

should comply EN 50160-2010. 

- Luminaire corresponds to the protection classification IP by IEC 60529. 

- Diffuser type: Silicate protective glass. 

- Further information about luminaire's dimensions shown in the table, please see "Overall and installation 
dimensions" section. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SKYLINE LED/M

Page 1: ...SKYLINE LED M Manual ...

Page 2: ...rature Rated power consumption tolerance 10 Nominal values of luminous flux weight tolerance is 10 Rated CCT tolerance 300К The supply mains must be protected from communication and electric impulse noise The main characteristics of line voltages at a network user s supply terminals in public AC electricity networks should comply EN 50160 2010 Luminaire corresponds to the protection classification...

Page 3: ...ICE Never work on the luminaire when voltage is switched on Do not operate the luminaire without protective grounding for class I luminaires Position the luminaire to avoid long viewing into the luminaire at a distance of less than 0 5 m Only operate the luminaire if the diffuser is undamaged Unauthorized disassembling modification and repair is prohibited In case of malfunction the luminaire shou...

Page 4: ...eaned with soft cloth and mild detergent 1 Switch mains power off Unpack the luminaire 2 Strip mains cable according to dimensions shown 3 Release cable connector s nut when available on luminaire side remove bushing on the other side and pull out terminals block Connect mains cable having put it through bushing and observing polarity shown Tighten bushing and cable lock nuts tightening torque 2 5...

Page 5: ...east 18 Nm of torque Lock the screw with hexagonal nuts 3 4 3 Release screw 4 if needed Set luminaire tilt angle needed using marks on the bracket marks intervals 10 turn intervals 5 Tighten the screw 4 with at least 18 Nm of torque ATTENTION Luminaire lifting and carrying by mains cable is not allowed it may cause moist protection failure cable and luminaire s internal circuits damage Dimensions ...

Page 6: ...les etc in case the repair site is not readily accessible The statutory warranty period is determined by the applicable law and may vary from country to country The manufacturer undertakes statutory warranty obligations in the amount and within the time frame stipulated by the applicable law Warranty period 60 months from date of delivery subject to terms and conditions specified herein and on the...

Page 7: ...Cd NiMh batteries Temperature range 5 to 40 C When storing for more than 6 months it is recommended to refresh batteries 5 cycles of charging discharging Transportation in manufacturer s package could be done by any mode of transport as long as protection from mechanical damage and precipitation is provided ACCEPTANCE CERTIFICATE The luminaire meets the requirements of applicable EC directives Man...

Reviews: