1. Cleaning period
:
In order to ensure the light fixture to be operated normally, it should keep the
lights clean, the cleaning period generally is one month, if the light is used in a environment with
dust ,or near to the smoke machine, bubble machine or snow machine, the cleaning period should
be shortened.
2. Cleaning Method:
◎
If there is dust inside the lights, firstly use the vacuum cleaner, gasbag or air gun (with pressure)
to blow the dust on the surface gently, or use a soft brush to wipe it
;
◎
Clean the optical lens, use the odorlessness tissue paper or cotton cloth to wipe the granular
material, then, use the cotton cloth soaked with ethanol (alcohol) or odorlessness paper to
remove dust and odor residue, lastly, use the distilled water for final cleaning, then dry it with a
soft cotton cloth;
◎
clean the color wheel, Gobo wheel and optical lenses ,because they are easy to be scratched,
so do not use destructive solvents for cleaning
;
◎
The other parts should be cleaned by the soft cotton cloth;
◎
Clean the focus, zoom and other sliding parts should adopt the high and low temperature
resistant lubricating oil, do not use unqualified oil to effect mechanical slide
;
◎
The lens and other rotating parts must be inspected regularly, keep them clean and stable,
if there is a obvious damage or looseness, it is necessary to replace or reinforce to prevent the
accident.
3
.
Cleaning attentions:
◎
All the lights in the cleaning and maintenance must be power off, completely disconnect from
the power, and move the light on the desk or on the ground.
◎
Do not use any paper or cloth which will produce the crumbs to clean the inside of the light.
Do not use any destructive solvent except the special cleaning solution or absolute alcohol,
and do not flush the lamp with water.
◎
Do not touch the glass bulb by hands directly to avoid the fingerprints which will lead to the
uneven heating and bulb burst.
◎
Attention intensity when clean rotation Gobo & color wheel and strobe plate to avoid the
deformation and interference, do not collide and shift the electronic induction element to keep
sensor function correctly.
◎
Do not pull the power and signal connection cables inside the light strongly to avoid the
abnormal connection.
◎
After cleaning, check the cleaning parts for deformation, stripping, disconnection or other
abnormality, make sure the alcohol and other flammable materials is completely volatile away
after cleaning, then switch on the light to avoid the fire.
Maintenance methods and attentions