background image

LIGHT PROGRESS 

 

 

 

 

 

 

 

 

 

       STICK-NX [eng]

 

 

 

gen-2021 

 

Pag. 9/16

 

 

MAINTENANCE 

 

 

UV LAMP

 

 
 

Lamp maintenance is very important because UV-C light emitted by 
the source is not visible to the eye, so, although you see the lamp 
ON, its germicidal effect may not be sufficient to performs disinfec-
tion treatment. 

Before reaching the lamp, 

ALWAYS 

switch off power supply  

If UV-C lamp gets dirty (or gets dusty) clean it with a clean cloth and al-
cohol, and avoid touching the glass part with hands. To check UVC lamp 
life number of hours, correct product code of the spare UV lamp please 
refer  to  table  1.  The  lamp,  once  reached  the  timing  for  replacement, 

must be replaced

, this operation is carried out as follows:  

 

•  Loosen  the  ring  nuts  on  the  lamp  housing  and  let  them  slide 
along the lamp; grab the lamp at the 2 ends and pull it in a direc-
tion parallel to the lamp. 
• Repeat the steps in reverse to insert the new lamp.

 

 
 

TROUBLESHOOTING 

 

 UV LAMP

 

 

See MAINTENANCE. 
 

BALLAST

 

 

All UV-STICK models are supplied with electronic ballasts 
which  guarantees  an  emission  of  15%  more  if  compared 
with traditional ballasts. Furthermore, lamps are not influ-
enced  by  environment  temperature  that  can  goes  until  -
20°C.  Finally,  the  switching  on  is  immediate,  with  no 
starter, and for this reason lamps last longer. 
To  preserve  the  original  features  of  original  IP  protection 
and isolation class, and to maintain all the characteristics 
that  guarantee  a  long-lasting  life  of  this  product,  the  bal-
last  replacement  must  be  done  by  qualified  technicians 
verified  by  Light  Progress.  In  case  of  necessity,  please, 
send the device back to our facility for any kind of repairs. 
If  this  is  not  possible  you  can  order  the  entire  supply 
channel for replacement (for code, see Table 1). 

USE 
PROTECTIVE 
GLOVES 

 

WEAR  

 

PROTECTIVE 
GLASSES  

Summary of Contents for UV-STICK NX Series

Page 1: ...GHT PROGRESS STICK NX eng gen 2021 Pag 1 16 UV STICK NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV STICK E40H NX UV STICK E75H NX UV STICK E2 40H NX NT UV STICK E2 75H NX...

Page 2: ...e maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in ca...

Page 3: ...assage of property and accompany the device until its demolition To request the instruction manual updated and to ask all other information needed it s possible to contact the Light Progress technical...

Page 4: ...of bacteria Bacillus E coli Clostridium Legionella Vibrio Salmonella Pseudomonas Staphylo coccus Streptococcus etc is obtained at the distance of 10 cm UV STICK NX can be installed in any type of env...

Page 5: ...SAVINGS The treatment is immediate and ready for use The maintenance is minimal with low costs of both energy consumption and repairs g NO CHEMICAL PHYSICAL ALTERATION The cold and dry treatment of th...

Page 6: ...pace covered by the UV STICKS NX devices is shown in Table 1 The final result of the disinfection will still be made dependent on the amount of germs coming in from the external environment To fit the...

Page 7: ...NS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that the device will be installed w...

Page 8: ...TER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase terminal n 3 Wire n 3 3 Line 230V 50Hz Phase Power line 230V 50Hz Neutral terminal n 4 Wire n 4 4 Line 230V 50Hz Neutral Electr...

Page 9: ...ends and pull it in a direc tion parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING UV LAMP See MAINTENANCE BALLAST All UV STICK models are supplied with electron...

Page 10: ...986 x 65 x 170 WEIGHT Kg 1 5 2 3 4 TREATED VOLUME m3 from 20 to 40 from 40 to 65 from 25 to 50 from 50 to 85 TREATED SURFACE m2 from 7 to 13 from 14 to 25 from 10 to 18 from 18 to 30 SPARE PARTS UV L...

Page 11: ...e parts or consumables Compatibility is assured only by use of products pur chased from or recommend by Light Progress Damages caused by modification of device system without Light Progress previous c...

Page 12: ...ery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 General...

Page 13: ...____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________...

Page 14: ..._________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _______________________...

Page 15: ..._________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _______________________...

Page 16: ...gen 2021 Pag 16 16 Loc San Lorenzo 40 52031 ANGHIARI AR ITALIA TEL 0575 74 92 55 FAX 0575 78 99 29 PRODUZIONE ANGHIARI Loc San Lorenzo 40 CASTIGLION F NO Loc S Antonino 40 Http www lightprogress it E...

Reviews: