CONVENTIONAL SYMBOLS NOTICED ON DEVICES

 

 
 
 
 

 

SUBSTITUTED ITEMS MUST BE PERFORMED RESPECTING THE LOCAL LAWS. 

 
 
 
 

 

RECYCLE THE STUFFS THAT COMPOSES THIS PRODUCT. 

 
 
 

 

 
OBLIGATION TO CONSULT THESE INSTRUCTIONS BEFORE USE THIS PRODUCT 

 
 
 

DANGER OF ELECTRICAL SHOCK; REMOVE TENSION TO THE SYSTEM BEFORE PERFORMING 
ANY OPERATION. 

 
 
 
 

 

GENERIC DANGER. 

 
 
 
 

 

DANGER OF EXPOSITION TO ULTRAVIOLET UV-C RAYS. 

 
 
 
 

 

THIS DEVICE RESPECTS THE ROHS NORMS. 

 
 
 

 

USE PROTECTIVE GLOVES 

 
 
 

 

WEAR PROTECTIVE GLASSES 

 
 

STORAGE OF THIS MANUAL

 

 

 

 

ATTENTION!

 

 

 

This instruction manual must be preserved and be ever at disposal to consultation; it must follow the device in 
case of passage of property, and accompany the device until its demolition

 

To request the  instruction  manual updated  and to  ask all other information  needed, it’s possible to contact the Light 
Progress’ technical office. 
 

DEMOLITION AND DISPOSAL 

 

Do  not  dispose  of  these  products  as  unsorted  municipal  waste,  but  collect  them  separately  as  a  special 
waste and  entrust  them  to  specialized  waste  disposal  companies.  Disposal  should  be  in  accordance  with 
Legislative Decree No. 151/2005 (WEEE - Italy), or the law of the country where disposal will occur (WEEE 
- EC). In case of failure to comply with laws or illegal disposal heavy penalties are provided. The apparatus 
consists of plastic parts, electronic components, metal, UV  lamps containing mercury (substances danger-

ous for the environment and human health). The dealer is available to the withdrawal of the apparatus used.

 

Summary of Contents for UV-STICK NX Series

Page 1: ...GHT PROGRESS STICK NX eng gen 2021 Pag 1 16 UV STICK NX Germicidal UV C Device for Disinfection by Direct Irradiation MODELS UV STICK E40H NX UV STICK E75H NX UV STICK E2 40H NX NT UV STICK E2 75H NX...

Page 2: ...e maintenance or cleaning ensure that the appliance is switched off and unplugged from the mains supply Should the appliance become faulty please contact our authorized Service Centre direct and in ca...

Page 3: ...assage of property and accompany the device until its demolition To request the instruction manual updated and to ask all other information needed it s possible to contact the Light Progress technical...

Page 4: ...of bacteria Bacillus E coli Clostridium Legionella Vibrio Salmonella Pseudomonas Staphylo coccus Streptococcus etc is obtained at the distance of 10 cm UV STICK NX can be installed in any type of env...

Page 5: ...SAVINGS The treatment is immediate and ready for use The maintenance is minimal with low costs of both energy consumption and repairs g NO CHEMICAL PHYSICAL ALTERATION The cold and dry treatment of th...

Page 6: ...pace covered by the UV STICKS NX devices is shown in Table 1 The final result of the disinfection will still be made dependent on the amount of germs coming in from the external environment To fit the...

Page 7: ...NS We suggest you to let a qualified electrician to install this device following these instructions and the electrical scheme and following the CEI norms Make sure that the device will be installed w...

Page 8: ...TER ST Red wire for LED terminal n 2 Wire n 2 Power line 230V 50Hz phase terminal n 3 Wire n 3 3 Line 230V 50Hz Phase Power line 230V 50Hz Neutral terminal n 4 Wire n 4 4 Line 230V 50Hz Neutral Electr...

Page 9: ...ends and pull it in a direc tion parallel to the lamp Repeat the steps in reverse to insert the new lamp TROUBLESHOOTING UV LAMP See MAINTENANCE BALLAST All UV STICK models are supplied with electron...

Page 10: ...986 x 65 x 170 WEIGHT Kg 1 5 2 3 4 TREATED VOLUME m3 from 20 to 40 from 40 to 65 from 25 to 50 from 50 to 85 TREATED SURFACE m2 from 7 to 13 from 14 to 25 from 10 to 18 from 18 to 30 SPARE PARTS UV L...

Page 11: ...e parts or consumables Compatibility is assured only by use of products pur chased from or recommend by Light Progress Damages caused by modification of device system without Light Progress previous c...

Page 12: ...ery Guards General Requirements for the Design and construction of fixed and movable guards UNI EN ISO 13849 1 2016 Safety of Machinery Parts of the Control System related to the Safety Part 1 General...

Page 13: ...____________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ ____________________...

Page 14: ..._________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _______________________...

Page 15: ..._________________ ____________________________________________________ ____________________________________________________ ____________________________________________________ _______________________...

Page 16: ...gen 2021 Pag 16 16 Loc San Lorenzo 40 52031 ANGHIARI AR ITALIA TEL 0575 74 92 55 FAX 0575 78 99 29 PRODUZIONE ANGHIARI Loc San Lorenzo 40 CASTIGLION F NO Loc S Antonino 40 Http www lightprogress it E...

Reviews:

Related manuals for UV-STICK NX Series