INPUTS
I1
Label
PIT SAFETY AND EMERGENCY BUTTON
Description
It deactivates if one of the pit safety devices or the manual emergency descent button are
triggered.
STANDBY only
ON
SQ_PER closed and SQ_FF closed and SB_MEM closed
INCORRECT STATUS
a.
check that the pit stop safety device has not triggered, SB_PEF terminal XF7;
b. check that the safety feature given by the pit safety device has not triggered, SQ_FF terminal
XF6;
c.
check that the safety feature provided by the emergency button on the FEM panel has not
triggered, SB_MEM terminal XF9.
I2
Label
OVERTRAVEL SAFETY DEVICE
Description
It deactivates if the overtravel contact is triggered.
STANDBY only
ON
SQ_EXC closed
INCORRECT STATUS
a.
check the car position and that SQ_EXC is not activated;
b. check the wiring on the XQ8 terminal.
I3
Label
CAR SAFETY DEVICES
Description
The car deactivates if one of its safety devices is triggered
STANDBY only
ON
SQ_PER closed and SQ_BOR closed and SQ_MAD closed and SB_PEC closed and SQ_COL closed
INCORRECT STATUS
a.
check that perimeter safety device has not triggered, SQ_PER terminal XQ12;
b. check that the edge safety device (above the platform pushbutton panel) has not triggered,
SQ_BOR terminal XQ9;
c.
check that the safety device on the wear of the lead screw (near the screw oiler) has not trigge
-
red, SQ_MAD terminal XQ11;
d.
check that the safety feature provided by the stop button has not triggered, SQ_PEC terminal
XQ4;
e.
check that the safety feature provided by the cover panel (under the platform pushbutton
panel) has not triggered, SQ_COL terminal XQ10.
I4
Label
CAR GATE SAFETY DEVICE
Description
It deactivates if the gate stays open
STANDBY only
ON
SQ_APC closed and SQ_ABC closed
INCORRECT STATUS
Check that safety contacts of the gate are closed.
I5
Label
FLOOR PRELIMINARY CONTACTS SAFETY DEVICES
Description
It deactivates if one of the floor doors is open.
STANDBY only
ON
SQ_APP closed
INCORRECT STATUS
Check that all floor doors are closed and that all preliminary contacts are closed SQ_APP termi
-
nal XF2.5 and XF2.6.