Scale
© Lift-Rite 242484-017
27
Or
1. Depress the
button.
2. Depress the
∧
button to go up a value or press the
∨
button
to go down a value until the required value is reached.
3. Depress
<
to change to the next digit.
- Repeat this procedure until the required value is displayed.
4. Depress
↵
to accept the new value.
- The set-point value is activated and the display returns to
the weighing mode.
- The display shows "tare" and the indicator automatically
tares out the scale after the scale has been stable for a few
seconds.
ATTENTION!
Be sure the container is already in place at this moment!
Filling and dosing:
- The display shows the net value and the pointers stp1 and
stp2 are on.
- Relays 1 and 2 are closed.
- As soon as set-point 1 is reached, pointer stp1 will turn off
and relay 1 will be opened.
- As soon as set-point 2 is reached, pointer stp2 will turn off
and relay 2 will be opened.
- The display shows "done" for a few seconds and will return
in the normal weighing mode.
- The net weight is displayed. A printout may be made at
this point.
It is possible to cancel the filling or dosing procedure at any time
by pressing the CE key.
The printout will show the following:
- The gross weight is the weight of the container with rest
material.
- The tare weight is the weight of the container with material
before dosing.
- The net weight will show a minus sign as token of weight
being removed from the scale.