background image

[email protected]

[email protected]

CLEANING / MAINTENANCE INSTRUCTIONS

Warm prompt : 

After long-time operation, dust accumulation on the pre-filters and the wet curtain would 

affect the airflow and air purify. Please clean the machine regularly.

(1). Clean pre-filter

Turn off the power, loose the screws, then pull out the pre-filter, clean it with soft brush 

and mild detergent, rinse by water and dry under the sunshine.

(2). Clean wet curtain

Turn off the power, loose the screws in the back-cover plate, take out the back-cover plate.

Loose the plastic nuts on the wet curtain, the side of wet pad can be emoved. clean it with 

soft brush and mild detergent, rinse by water and dry under the sunshine, then install back 

to the machine.If the dirt is hard to remove after long-term usage, please change a new 

wet curtain.

(3). Clean the surface

Turn off the power, clean it with mild detergent and soft cloth. Notice: control panel shall 

not be touched by water.

FAULT AND MAINTENANCE

- 10 -

- 11 -

Possible results

Solutions

"Failure"

phenomenon

(1). Water-pipe blockage. 
(2). Without long-term water 
cooling. 
(3). Poor water quality to 
produce scale make central 
shaft stuck.

(1). Use a small brush to clean the pipe 
and keep smooth water flow.
(2). Long time for cooling without water 
cause pump damaged, need to 
replace a new water-pump. 
(3). Remove the shaft, clean the dirt on 
the surface, add proper lubricating oil 
insert it, and debug the shaft.

Water pump

doesn't work

(1). The fan blades are stuck.
(2). The filter is blocked.
(3). Fan blade is not fixed.
(4). Main control panel error.

(1). Check the fan blade.
(2). Clean or replace filter.
(3). Replace fan blade.
(4). Replace main control panel.

No wind or wind

speed is too slow

(1). Main control panel Button 
is broken.
(2). The wiring of the motor 
and control panel falls off.

(1). Replace main control panel.
(2). Replace a new wire to connect 
the motor and control panel.

Motor is out

of control

(1). Drain valve is broken.
(2). Rubber band drop.

(1). Replace the drain valve.
(2). Add a new rubber band.

Drain valve

is leaking

Store the air cooler in a cool, dry location when not in use. To prevent dust and dirt 

build-up, use the original packaging to repack the unit.

STORAGE