MESSAGE
DESCRIPTION
POSSIBLE CAUSE
REMEDy
“Stop key activated.”
MIB has decoded
a Stop key press.
System aborts
workout.
Faulty Activity Zone
keypad.
Check proper operation of keypad in
diagnostics and replace if necessary.
“Unable to attain
target speed.”
1
Reported if the motor
controller was unable
to attain the desired
user’s speed after a
given amount of time.
Line voltage low, unit
overloaded; too much
weight for speed
requested.
Worn belt and/or
deck.
Check belt & deck for signs of excessive wear
and replace if necessary.
"Miscellaneous
interface
communication
error."
Typically this is
reported if SBC was
unable to properly
activate the belt and/
or incline motors.
Communications
error with the motor
controller.
See “Module communication error.”
“Workout initialization
time-out.
resetting system.....”
System was unable
to enable the belt
and/or incline motors
while starting a
workout.
Communications
error with the motor
controller.
See “Module communication error.”
“Please replace
emergency stop
switch.”
Emergency stop
(tether) is replaced,
but console still gives
this message.
Tether / magnet loose
or not installed;
Poly-resettable fuse
(PTC2) or Q5 on MIB
are open;
Over-current
condition on
emergency stop relay
on motor controller.
Verify tether / magnet are properly replaced /
installed.
Replace MIB.
Replace motor controller.
1
When user sees this message the belt speed will decrease automatically. If user is already at minimum speed (i.e.
0.5 mph) then workout will enter Pause mode. If speed is more than one mph/kph below target speed then speed is
reduced by ½. If speed is closer to target when an “Unattained…” occurs then speed is decremented between 0.1 to
0.3 mph/kph.
2
A simple test to determine if console is communicating with the motor controller is to cycle power and listen for
beeps from the MIB board. The MIB will beep once after it gets power followed by three additional beeps if it can
successfully communicate with the motor controller. This process is done before the main Application on the SBC is
up and running (i.e. before you see the “Splash” screen which contains the word “initializing” on it).
CN 18
M051-00K70-B111
Error Message Tables
Engage™ and Inspire™ Consoles