11.
Storage
Store the belt in internal, dry and clean areas. Protect it from direct sunlight and high
temperatures. Do not put anything on the treadmill. Avoid the static electricity that
can interfere with the correct functioning of the meters or even damage it.
In winter store and use the treadmill in rooms with adequate humidity.
12.
Causes and resolution of potential failures
No.
Fault
Causes
Resolution
1
The treadmill can not
be started
The security key is not in the
correct position.
Set the security key to the correct
position.
The main switch is off (in
position "0")
Turn on the main switch to
position "1".
2
The control panel does
not display any
information.
The control panel and the
control unit are disconnected.
Remove the engine cover and
reconnect the panel with the unit.
3
The heart rate is not
displayed.
The sensors are not sufficiently
damp.
Lightly moisten the sensors with
water.
Sensing is interfered with by
another electromagnetic field.
Move the treadmill to another
location. Avoid contact with
electromagnetic waves.
4
Incline setting does not
work.
The motor cable is not
properly connected.
Remove the engine cover and
connect the cable properly.
5
The treadmill is sliping.
The seat belt is not tightened.
Tighten the running belt
according to Chapter 8.
6
The treadmill deflect to
the sides.
The treadmill is not adjusted.
Adjust the deviation of the
treadmill in accordance with
Chapter 8.
If you are unable to remedy the failure even with the above solutions, please contact
our specialist service as soon as possible.
13.
Error messages on the display
If there are any problems in running on the treadmill, the type of fault will appear on
the display. In the event that such a fault occurs, please contact our service center.
Code of
fault
Description of fault
Troubleshooting
E-01
Cable break or improper connection.
Malfunction of console or PCB.
Check to make sure all cables and lines are well
connected.
Replace the console or PCB.
E-02
The power line of motor is not well
connected or the loose of carbon
brush leads to the improper
connection.
The power tube of PCB is broken or
short circuited.
Explosion impact
Check to make sure the power line and the
carbon brush of the motor is well connected.
Check and replace the power tube is it is broken.
E-05
Over current protection
Check if there is too much friction, and use
silicon oil to reduce the friction.