INSTALLATION MANUAL FOR TFP AIR CLEANER 

TFP2000 (Wholehouse Model) 

TFPC2000 (Portable Console Model)

The TFP can be installed in several different ways.  
Please read all suggested methods before 
attempting installation.

ATTENTION

The furnace fan and/or HRV must operate 
continuously for Type 1 and Type 2 installations.  
If they do not operate continuously, then 
interlocking them electrically with the TFP is 
acceptable.   Consult a certified electrician.

ATTENTION

WHOLEHOUSE AND PORTABLE

CONSOLE MODELS

Summary of Contents for TFP2000

Page 1: ... and product development specifications ratings and dimensions are subject to change without notice TFP 06 0204 INSTALLATION MANUAL FOR TFP AIR CLEANER TFP2000 Wholehouse Model TFPC2000 Portable Console Model The TFP can be installed in several different ways Please read all suggested methods before attempting installation ATTENTION The furnace fan and or HRV must operate continuously for Type 1 a...

Page 2: ...lenum Install ducting to join TFP to the return air plenum Fig 2 NOTE Do not support the weight of the TFP on the duct Duct must be open and not pinched NOTE Due to possible noise transfer through the duct system it may be preferable in some situations to hang the TFP a short distance from the plenum and connect by running flexible ducting between them Four nylon hanging straps are provided for th...

Page 3: ...e 3 A relief opening or breathing T is required to prevent pressure differences 4 A short piece 1 2 foot of flexible ducting should be used on both sides of the TFP Fig 3 This will reduce vibration and noise transfer if present NOTE Please refer to the HRV installation manual for proper ducting of that appliance Type 2 Installation Breathing T is designed to assist in neutralizing pressure differe...

Page 4: ... hard to estimate when the collectors will need to be changed Because of the way air moves through the TFP the collectors are divided into 3 separate sections Collectors 1 2 then 3 4 and then 5 6 Collectors 1 2 will need to be replaced before the others then 3 4 and so on You may want to change 1 2 again before 3 4 or 5 6 The collectors will slide out Some discolouration of the collector medium ca...

Reviews: