TFP Directly Connected to 

Forced Air Heating System

1.  Install 6” oval port collar (provided) on top and

bottom of TFP (Fig. 1). Use (4) 8/32” X 3/8”
screws (provided).

2.

Remove protective backing from pieces of
foam and stick them to the 4 corners of the TFP
on the side being mounted against the plenum.

3.

Remove the 4 mounting bolts from the back of the
TFP cabinet. (Fig. 1) 

4.

Attach top and bottom mounting brackets
(provided) vertical to the TFP cabinet and
reinstall mounting bolts.

5.

Lift the TFP into position. Edge of TFP must be 
positioned on plenum to allow clearance 
needed for latches.

6.

Install the (4) 8/32” X 3/4” mounting screws
(provided) through the brackets and into position. 
Tighten and secure.

7.

TFP should now sit securely against the plenum 
with the foam in between.

8.

Cut 2 - 6” holes in the plenum. Install ducting to 
join TFP to the return air plenum (Fig. 2).

NOTE: Do not support the weight of the TFP on
the duct. Duct must be open and not pinched. 

NOTE: Due to possible noise transfer through 
the duct system, it may be preferable in some 
situations to hang the TFP a short distance from
the plenum, and connect by running flexible 
ducting between them.  Four nylon hanging straps
are provided for this option.

Type 1 Installation

* Direct connect to furnace/air handler return, or hang
separately and connect to plenum with flexible ducting.

TYPE 1 INSTALLATION

TFP

TFP air cleaner

TFP

TFP

Figure 1

T
F

P

Cold Air Return

Air flow direction

6" port collars

Access door

Power supply

Mounting bracket

Ducting (not included)

Clean (filtered) air port

Mounting bracket

Foam gaskets

FURNACE

Air Flow

Supply Plenum

Install plate here

1" Height

Figure 2

Round port bent to oval

Simply bend a standard duct fitting to the correct shape,
and attach to the oval port using the same method as
for a round port.

Summary of Contents for TFP2000

Page 1: ... and product development specifications ratings and dimensions are subject to change without notice TFP 06 0204 INSTALLATION MANUAL FOR TFP AIR CLEANER TFP2000 Wholehouse Model TFPC2000 Portable Console Model The TFP can be installed in several different ways Please read all suggested methods before attempting installation ATTENTION The furnace fan and or HRV must operate continuously for Type 1 a...

Page 2: ...lenum Install ducting to join TFP to the return air plenum Fig 2 NOTE Do not support the weight of the TFP on the duct Duct must be open and not pinched NOTE Due to possible noise transfer through the duct system it may be preferable in some situations to hang the TFP a short distance from the plenum and connect by running flexible ducting between them Four nylon hanging straps are provided for th...

Page 3: ...e 3 A relief opening or breathing T is required to prevent pressure differences 4 A short piece 1 2 foot of flexible ducting should be used on both sides of the TFP Fig 3 This will reduce vibration and noise transfer if present NOTE Please refer to the HRV installation manual for proper ducting of that appliance Type 2 Installation Breathing T is designed to assist in neutralizing pressure differe...

Page 4: ... hard to estimate when the collectors will need to be changed Because of the way air moves through the TFP the collectors are divided into 3 separate sections Collectors 1 2 then 3 4 and then 5 6 Collectors 1 2 will need to be replaced before the others then 3 4 and so on You may want to change 1 2 again before 3 4 or 5 6 The collectors will slide out Some discolouration of the collector medium ca...

Reviews: