3.1.2
Automatic reclosure
Automatic reclosure is activated after a preset PAUSE TIME.
In this mode, by pressing the ‘
STEP
’ key, the automation changes its motion according to the sequence 1 –
OPEN
2 –
PAUSE
3 –
CLOSE
4 -
PAUSE
;
for example, if the automation is opening and one selects the step command on the remote control, the automation stops in pause; conversely, if the
automation is closed, when the step command is given it opens.
PAUSE TIME
is intended as the pause time before automatic re-closure.
Press
and
to set the various
PAUSE TIME
values.
Wait 25 seconds or press
again to quit.
OPEN » PAUSE » CLOSE » PAUSE
Press
the green LED
(DX)
switches on:
• if none of the LEDs
is switched on, automatic
reclosure is not enabled, to enable it press
;
• if at least one of the LEDs
is switched on,
automatic reclosure is enabled, to deactivate it press
until all the LEDs switch off.
LEDS ON
PAUSE TIME
AUTOMATIC RE-CLOSURE IS NOT ENABLED
5 s
10 s
30 s
60 s
120 s
3.2
Functions
3.2.1 Courtesy light
The courtesy light function switches a light on during any automation movement.
The light remains on after the last manoeuvre for a 30-second period.
3.2.2 Deceleration in opening and closure
The automation decelerates in the final stretches of opening and closure.
3.1.3
OPTION MENU 1
Press to enter OPTION menu, press repeatedly to select further options, the flashing led shows the position, by pressing
the function is activated (red led on), by pressing button– the function is desactivated.
LEDS ON
OPTIONS 1
NO FUNCTIONS ACTIVATED
Block of appartment: Step-by-step in opening
Modifies the function in: OPENING-STOP-CLOSING-STOP
Elimination small reversal
Clock Option - 6 -9 for connextion use
Profile Overhead door recomeded use with APRB