background image

14   MANUFACTURER’S DECLARATION OF CONFORMITY

                                                          Declaration of

                                                                                                 conformity

                                     under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity).

     

LIFE home integration

                                                                          Via Sandro Pertini  3/5

                                                              31014 COLL E UMBERTO (TV) Italy

                                                                       

declares that the following product:

                                                                                   

OP3-OP5

                                            satisfies the essential requisites established in the following directives:

• 

Low voltage directive 73/23/EEC and subsequent amendments,

• 

Electromagnetic compatibility directive 89/336/EEC and subsequent amendments,

• 

Radio and telecommunications equipment directive 1999/5/EC and subsequent amendments.

                                                                                   and satisfies the following standards:

• 

EN 12445:2000  

 

Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors – testing 

                                                                 methods 

• 

EN 12453:  

 

Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors - Requisites.

• 

EN 60204-1:1997                   Machinery safety – Electric equipment of the machine – Part 1: general rules.

• 

EN 60950  

 

Information technology equipment - Safety - Part 1: General requisites

• 

ETSI EN 301489-3:2001  

Electromagnetic compatibility for radio equipment and appliances.

• 

EN 300220-3:2000  Radio equipment and systems – short band devices – Technical characteristics and testing methods for radio 

                apparatus with a frequency of 25 to 1000 MHz and powers of up to 500mW.

The Manufacturer also declares that it is not permitted for the abovementioned components to be used until such time as the system in which they are 

incorporated is declared conform to directive 98/37/EC.

C

 

 

 

 

 

 

Position:   

 

Managing Director 

 

 

 

 

 

 

Signature: 

 

_________________

Summary of Contents for Optimo OP3

Page 1: ...ADVERTENCIAS PARA LA INSTALACI N EL USO Y EL ACTUADOR LINEAL ELECTROMEC NICO PARA CANCELAS INSTRUCTIONS ET CONSEILS POUR L INSTALLATION L UTILISATION ET ACTIONNEUR LINEAIRE ELECTROMECANIQUE POUR PORT...

Page 2: ...ety in the usage of motorised doors testing methods EN 12453 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 60204 1 1997 Machinery safety Electri...

Page 3: ...e uma automatiza o tipo ver figura Tab 1 Bestandteile und Vorrichtungen eines Musterantriebs siehe Abbildung 2 OPTIMO Tab 2 Description of the contents of the OPTIMO operator pack see figure Tab 2 Des...

Page 4: ...800 Lubrication Type grease Net rod travel mm 300 450 300 450 Thermal protection device C 140 NO Stop plate YES YES YES YES YES YES Electromechanical limit switches YES YES YES YES YES YES Optic encod...

Page 5: ...E OP3 745 mm E OP5 895 mm 80 2 2 Typical installation A TWO LEAF SYSTEM The definition of leaf 1 and leaf 2 of the gate is essential for automation operation Leaf 1 is the fir Leaf 2 is the second B...

Page 6: ...hat the surface is suitable for clamping with screws or by means of welding d Fix with screws or by means of welding the rear bracket 1 to the pillar in the established position e Make sure that the r...

Page 7: ...d opening position loosen the suppor lock again by tightening 9 Definitively fix the front bracket 2 of the operator to the leaf of the gate choosing the clamping means to suit the material of the lea...

Page 8: ...led versions have an extra cable for the encoder and limit switch signal 2 wired cable The 230V models come with a capacitor which is housed in the control unit The capacitor is connected in parallel...

Page 9: ...OP324 OP524 9 10 9 5RI0950000 OP3 OP3L OP3UNI OP3LUNI OP5 OP5L OP5UNI OP5LUNI 10 5RI0960000 OP324 OP324UNI OP524 OP524UNI 11 12 11 5RI0970000 OP3 OP3L OP324 12 5RI0980000 OP5 OP5L OP524 OP3 OP5 DESCR...

Page 10: ...1030000 OPTIMO 18 5RI01040000 OPTIMO 19 5RI01060000 OPTIMO 20 5RI01070000 OPTIMO 22 5RI01080000 OP3 OP3L OP3UNI OP3LUNI OP5 OP5L OP5UNI OP5LUNI 18 23 23 5RI2750000 OP3UNI OP3LUNI OP324UNI OP5UNI OP5LU...

Page 11: ...es Safety in the usage of motorised doors testing methods EN 12453 Industrial commercial and garage doors and gates Safety in the usage of motorised doors Requisites EN 60204 1 1997 Machinery safety E...

Page 12: ...Address Via Sandro Pertini 3 5 31014 Colle Umberto TV Italia Telephone 39 0438 388592 Telefax 39 0438 388593 http www homelife it e mail info homelife it Numero verde LOGO...

Reviews: