background image

9

5. TANK FILLING AND WATER TREATMENT

•  Remove Black plug only for filling.  Fill at MAX 

resistance 

+

 sign only.  

•  Once filling is complete, insert tank plug into 

place.

1.  Filling requires a large bucket (not supplied) and the Fluid Rower Siphon (included).  Filling will take approximately 

4.5 gallons (17 liters) of water.

2.  Remove the tank plug on top of tank and insert the flexible tube into the rear of the tank while keeping the rigid 

hose in the bucket. 

Note: Where water quality is known to be poor, Life Fitness recommends the use of distilled water. 

3.  Move the adjuster knob to the plus sign (+), and begin filling. Note: The siphon valve must be closed to allow 

siphoning action to occur. Tip: Placing the bucket in an elevated position will allow the siphon to continually pump 
water into the tank. Do not fill past the calibration mark indicated on the tank!

Note: Opening the siphon valve will stop the pumping action. Use this feature to avoid water spillage when 

nearing filling completion. 

4.  Once filling is complete (to the proper calibration level as indicated on the tank), follow water treatment schedule 

as shown.

WATER TREATMENT PROCEDURE:

1.  Add one Water Treatment Tablet per full tank.

Note: The amount of water treatment can vary widely depending on the rower’s location and exposure to sunlight. 
DO NOT, UNDER ANY CIRCUMSTANCES USE OTHER TREATMENT TABLETS OTHER THAN THOSE SUPPLIED WITH 
YOUR ROWER. Your rower box contents include 4x Water Treatment Tablets, which is sufficient for several years 
of water treatment. Treat when water becomes discolored or shows signs of Algae/Bacterial growth. To purchase 
additional Water Treatment Tablets, please consult your nearest regional dealer/distributor or check our website at 
www.lifefitness.com 

CAUTION: Use a drop cloth under the tank when filling to avoid staining floor or carpet.  

WARNING: Do not insert fingers into tank!

TANK FILLING

Summary of Contents for Row HX

Page 1: ...Row HX Trainer Owner s Manual 1002735 0001 REV AB...

Page 2: ...many 41 0848 000 901 Switzerland Fax 49 89 31 77 51 99 Germany 41 043 818 07 20 Switzerland Service Email kundendienst lifefitness com Sales Marketing Email kundenberatung lifefitness com Operating Ho...

Page 3: ...stop exercising immediately Stop the machine immediately if any signs of excessive wearing is present on the belts pulleys and bungee cords Do not use unit until said parts are repaired or replaced Do...

Page 4: ...mmediately any defective parts and do not operate unit until all repairs are complete PROPER USAGE Do not use any equipment in any way other than designed or intended by the manufacturer It is impera...

Page 5: ...ing maintenance or repair of any kind is qualified to do so DO NOT ATTEMPT TO USE OR REPAIR ANY ACCESSORY APPROVED FOR USE WITH THE LIFE FITNESS EQUIPMENT WHICH APPEARS TO BE DAMAGED OR WORN Check all...

Page 6: ...ult of the Product s location alterations or modifications without our written authorization or by failure on your part to use operate and maintain the Row HX Trainer as set out in your Owner s Manual...

Page 7: ...fe Fitness office servicing your country contact information found at the front of this manual or visit the applicable local Life Fitness website to receive the specific warrnanty information for your...

Page 8: ...User Weight 330lb 150kg Minimum Safe Operating Surface Area 131 09 333cm Length x 67 71 172cm Width Dimensions 83 85 213cm Length x 20 47 52cm Width x 22 04 56cm Height The live area shall be not les...

Page 9: ...he tank Note Opening the siphon valve will stop the pumping action Use this feature to avoid water spillage when nearing filling completion 4 Once filling is complete to the proper calibration level a...

Page 10: ...int of finding the water slightly cloudy add a chlorine Tablet CAUTION It is recommended that a drop cloth be used under the fluid tank whenever the tank is open for water treatment Vertical Storage T...

Page 11: ...up or down The numbers 1 6 represent a guide line from which the proper length can be determined Secure the plate onto the mounting pegs and push down firmly to lock into position Tighten the Footstra...

Page 12: ...than 5 minutes will resume Distance TIME from saved values automatically Auto Power Down Over 5 minutes All values revert to zero after restart Computer Instructions TIME Auto start elapsed time 500M...

Page 13: ...VITY Console USB Connector Our FirstCoach provides an easy to use interface with functionality to record and view your rowing sessions Session Recorder On screen Ergometer Records 500m Time Heart Rate...

Page 14: ...500m time Row at a pace that keeps the water circulating continuously between strokes Progress a few minutes more each day until you are comfortable with 30 45 minutes training time 3 or 4 times a wee...

Page 15: ...ighten the Knobs or Bolts 2 Install the bracket onto the rower as shown 3 Tighten the Z Bracket knob to affix to row er Note Ensure the Z Bracket is secure be fore tightening 4 Stand rower up vertical...

Page 16: ...dred hours for cor rect tension and for signs of wear The Bungee Cord should last for many years If a Bungee Cord change is required please contact your local service representative or go online at w...

Page 17: ...isplay Check that the computer lead is connected properly If connected properly check sensor gap Contact your local service center if this fails to address the problem The Row HX Trainer computer does...