background image

   

LIFAN   Power   USA   

2205   Industrial   Park   Road   

Van   Buren,   AR   72956   

866-­‐471-­‐7464   

www.lifanpowerusa.com   

   

29   

Troubleshooting   

   

IF   THE   ENGINE   WILL   NOT   START:   

1.

 

Check   to   ensure   switches   are   in   the   “ON”   position.      (Both   unit   and   engine)   

2.

 

Check   engine   oil   level.      Your   unit   possesses   a   Low   Oil   Alarm   System   that   will   not   

allow   your   engine   to   start   if   the   oil   is   below   safe   operating   levels.      This   feature   is   

installed   to   increase   the   life   of   your   engine   and   prevent   engine   damage.      If   oil   

level   is   low,   fill   to   the   full   mark   on   dipstick.      Refer   to   the   Product   Specifications   

for   exact   oil   type   and   amounts.   

3.

 

Check   the   fuel   level   to   insure   adequate   fuel.      Add   fuel   if   necessary.   

4.

 

Remove   and   inspect   the   spark   plug   for   cleanliness   and   proper   electrode   gap.      If   

needed,   clean   or   replace   the   spark   plug.      Refer   to   Spark   Plug   Maintenance   in   the   

Maintenance   section   of   the   Owner’s   Manual   for   proper   procedure.   

5.

 

If   your   unit   will   still   NOT   start   after   performing   the   above   checks,   call   our   

customer   hotline   at   LIFAN   Power   USA   Toll   Free   1-­‐866-­‐471-­‐7464   or   take   your   unit   

to   an   authorized   Service   Center.   

NOTE:

      Periodically   on   the   initial   start-­‐up   or   after   the   unit   has   been   stored   

for   a   long   period   of   time,   the   float   for   the   “Low   Oil   Alarm   System”   will   stick   
to   the   bottom   of   your   oil   pan.      Locate   the   two   (2)   wires   to   the   Low   Oil   

Sensor   Diode   (refer   to   figure   on   the   right)   located   on   the   side   of   the   engine   

block.      Unplug   these   wires   and,   

only   after   ensuring   the   engine   is   full   of   oil,

   

start   the   engine   and   allow   to   run   until   warm   (normally   20   minutes,   as   this   

will   heat   the   oil   and   release   the   float   on   the   Low   Oil   Alert   System).      Then   re-­‐

plug   the   wires   to   the   terminals   on   the   Low   Oil   Alarm   Sending   Unit.   

   

UNIT   DOES   NOT   PROVIDE   ELECTRICAL   CURRENT:   

1.

 

Plug   in   a   small   appliance   or   tool   to   test.   

2.

 

Check   if   the   AC   (or   DC)   Circuit   Breaker   is   in   the   “ON”   position.      If   not,   place   in   

“ON”   position.      If   equipped   with   a   GFCI   receptacle,   re-­‐set   GFCI   Breaker   by   

pushing   in   the   reset   button   in   the   middle   of   the   GFCI’s   faceplate   (this   must   be   

done   with   the   engine   running).   

3.

 

If   your   unit   still   does   NOT   produce   electricity   after   performing   the   previous   

checks,   call   LIFAN   Power   USA   at   1-­‐866-­‐471-­‐7464,   your   dealer,   or   authorized   

Service   Center.   

   
   

Summary of Contents for 7000 Pro series

Page 1: ...7 0 0 0 7 0 0 0 i P L 8 5 0 0 i E 8 5 0 0 i E P L G E N E R A T O R S O WN E R SMA N U A L...

Page 2: ...iPL LF7000iPL CA LF8500iEPL LF8500iEPL CA PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATING YOUR NEW PORTABLE GENERATOR E Indicates this unit is equipped with Electric Start CA Indicates this unit is...

Page 3: ...the Owner s Manual For any questions visit www lifanpowerusa com or call 1 866 471 7464 3 Read the Owner s Manual prior to operating any equipment and familiarize yourself with the proper and safe ope...

Page 4: ...Specifications 5 Safety Instructions 6 Controls and Features 11 PRE OPERATING INSTRUCTIONS 14 Assembly 14 Battery Specifications 16 Generator Setup 17 Operation of Generator 20 Storing the Unit 24 Mai...

Page 5: ...or to operation Keep this Owner s Manual for assistance in the future such as proper maintenance schedules and tips to prolong the life and effective use of your unit If you require assistance please...

Page 6: ...11 LF190FDI13111 LF188FI13111 LF190FDI13111 Maximum Horsepower MHP 13 MHP 15 MHP 13 MHP 15 MHP Engine Displacement 389cc 420cc 389cc 420cc Starting System Recoil Recoil Electric Recoil Recoil Electric...

Page 7: ...k Plug 1 ea 1 ea 1 ea 1 ea Spark Plug Wrench 1 ea 1 ea 1 ea 1 ea Mobility Wheel Kit Yes Yes Yes Yes Battery not included N A 12V 100cca min 7 lx3 w N A 12V 100cca min 7 lx3 w 866 741I7464 Van Buren AR...

Page 8: ...xide can cause nausea or death ONLY operate generator outdoors Exhaust gas must be prevented from entering confined areas Direct exhaust gas away from windows doors ventilation and other openings Do n...

Page 9: ...is felt and then pull rapidly to avoid kickback Never start or stop engine with electrical devices plugged in and turned on Doing so is hazardous and will damage generator WARNING Generator produces p...

Page 10: ...f position Disconnect spark plug wire before transport or service WHEN STORING FUEL OR EQUIPMENT CONTAINING FUEL Store away from furnaces stoves water heaters clothes dryers or other appliances that h...

Page 11: ...ter is required under section 4442 of the California Public resources code WARNING Unintentional sparking can result in fire or electrical shock WHEN TESTING FOR ENGINE SPARK Do NOT check for spark wi...

Page 12: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 11 Controls and Features Read this Owner s Manual Completely and Carefully before Operating Generator...

Page 13: ...oil Starting Handle Pull Handle to Rotate Engine for Starting 10 Fuel Cock Valve Turn to OFF to Terminate Fuel Delivery to Engine 11 Air Cleaner Check Maintenance Schedule for Service Intervals 12 Cho...

Page 14: ...load required Upon demand the generator will enhance engine speed automatically to provide the correct electrical power the connected device requires The Auto Idle Control feature minimizes fuel consu...

Page 15: ...ea 12 Volt Power Cord with Plug Alligator Clips o 1 ea Nema14 30 Male Twist Lock Plug o RV Adapter Plug for 120 Volt 30amp Service Owner s Manual and Warranty Card Wheel Kit o 2 ea Never Go Flat Foam...

Page 16: ...rections NOTE Install Wheel Kit BEFORE Filling the Generator with Fuel or Oil Never Tip a Unit that contains Fuel or Oil 1 Tip Generator so Engine End is up 2 Slide Axle through both Mounting Brackets...

Page 17: ...with the brand battery available at your local retailer BATTERY SPECIFICATIONS Generator Model Length inch Width inch Amp hrs DC Voltage Volts LF8500iE 5 3125 in 3 1875 in 12 12V LF8500iEPL 5 3125 in...

Page 18: ...ilure and void warranty ADD ENGINE OIL Refer to the diagrams below 1 Place generator on level surface 2 Clean area around Oil Hole Dipstick Plug Unscrew Oil Hole Dipstick Plug 3 Fill with appropriate...

Page 19: ...h a fuel stabilizer or drained if the generator will not be started for thirty 30 days If using a fuel stabilizer follow the manufacture s recommended instructions for use Always use stabilizer with a...

Page 20: ...to Air Cleaner Maintenance in the Maintenance section of this Owner s Manual to ensure Air Cleaner Element is in operable condition GROUNDING THE GENERATOR Refer to Controls and Features section 1 Con...

Page 21: ...CAUTION Never start or shutoff the generator with electrical loads connected and in the operational mode on switch activated Starting or shutting off the generator with electrical loads activated may...

Page 22: ...0 Volt loads to the 240 Volt receptacles Always plug appliances into the generator with appliance in its OFF position 3 Plug in 12V DC load to the DC receptacle DC and AC power may be used simultaneou...

Page 23: ...CY TIME VFT METER The LF3750 LF3750 CA LF4000EPL and LF4000EPL CA models include a Voltage Frequency Time VFT Meter The VFT Meter has four 4 modes Start Up Mode 1 The run time for the cycle displayed...

Page 24: ...gine USAGE IN HIGH ALTITUDE REGIONS In regions with high altitude the standard carburetor produces overly dense combinations of fuel and air which result in decreased engine performance and increased...

Page 25: ...e section Do NOT re fill with oil until ready to use again 5 Remove the Spark Plug in accordance with the Spark Plug Maintenance in the Owner s Manual s Maintenance section Spray a lubricant such as W...

Page 26: ...ment Product Check your engine oil level prior to each use 1 Start your engine and let it warm up to get the oil warm and thinner Turn the engine On OFF switch to the OFF position Turn Fuel Valve to t...

Page 27: ...L MUST BE CHANGED ON A REGULAR BASIS FOR PROPER OPERATION AND RELIABILITY AND TO ALSO MAINTAIN THE WARRANTY ON THIS PRODUCT AIR CLEANER MAINTENANCE 1 Remove the clip item 9 in Air Cleaner A below or t...

Page 28: ...ENANCE NOTE Periodically you can get sediment or trash in your Carburetor Bowl Use the following procedures to clean 1 Turn the fuel cock valve to the OFF Position 2 Remove the carburetor bowl by remo...

Page 29: ...npowerusa com 28 Maintenance continued FUEL SYSTEM MAINTENANCE continued diagram below and either clean or replace the fuel filter element Re assemble the fuel filter element refer to Fuel Filter Elem...

Page 30: ...r USA Toll Free 1 866 471 7464 or take your unit to an authorized Service Center NOTE Periodically on the initial start up or after the unit has been stored for a long period of time the float for the...

Page 31: ...OT operate your power equipment within five 5 feet of any flammable materials 5 When refueling the power equipment never smoke or refuel near any flame or ignition devices Never refuel while the unit...

Page 32: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 31 Wire Diagram LF7000 L F7000 CA LF7000iPL L F7000iPL CA W iring D iagram...

Page 33: ...LIFAN Power USA 2205 Industrial Park Road Van Buren AR 72956 866 471 7464 www lifanpowerusa com 32 Wire Diagram continued LF8500iE L F8500iE CA LF8500iEPL L F8500iEPL CA Wiring D iagram...

Page 34: ...Opener 900 2400 Clothes Dryer Electrical 5400 1350 Curling Iron 1500 0 Iron 1100 0 Hair Dryer 1200 Watt 1200 0 Washing Machine 1000 3000 Security System 550 0 Air Compressor 1 3 HP 300 780 Quartz Hal...

Page 35: ...ting Watts Required 250 For this Example a Generator with a minimum of ___2175___ Total Running Watts and ___2425___ Total Starting Watts is required I Require a Generator with a minimum of __________...

Page 36: ...C will repair or replace at its option any part that is proven to be defective in material or workmanship under normal usage Repairs and or replacement will be made without charge for parts or labor A...

Page 37: ...rmation in this publication is based on the latest product information available at the time of approval for printing We reserve the right to make changes at any time without notice and without incurr...

Page 38: ...i l a b l e a t t h e t i m e o f a p p r o v a l f o r p r i n t i n g We r e s e r v e t h e r i g h t t o m a k e c h a n g e s a t a n y t i m e w i t h o u t n o t i c e a n d w i t h o u t i n c...

Reviews: