Operation of Generator
LOW OIL ALARM SYSTEM:
This model is equipped with a Low Oil Alert System designed to avoid engine damage from insufficient oil in the
crankcase. The Low Oil Alarm System will stop the engine automatically before the oil level in the crankcase drops
below safe operating levels. This will cause the RED Output Indicator Light to illuminate. Though the engine will stop
running, the ignition switch will remain in the “START” position. Turn to the “STOP” position.
STOPPING THE GENERATOR
Refer to Controls and Features section for diagram.
EMERGENCY SHUTDOWN
1.
Turn the Ignition Key to “STOP” position.
NORMAL SHUTDOWN
1.
Unplug all electrical loads or turn the main breaker to the “OFF” position.
2.
In order to stabilize internal equipment temperatures, allow the engine to run for 3--5 minutes under no
load.
3.
Turn the ignition switch to the “STOP” position.
4.
Allow unit to cool to ambient temperature before storage or transportation.
5.
Always transport the generator with the fuel valve in the “OFF” position. Failure to do so will result in
damage to the engine.
REMOTE SHUTDOWN
Press and hold the “OFF” button (marked with a padlock) on the remote start