29
OPERATION OF GENERATOR
HOW TO USE YOUR GENERATOR
• Checking the appliance(s) for proper operation, electrical shorts, and malfunctions. Also ensure
the generator has the ability to provide the required starting and running watts of the connected
appliance(s).
• Ensuring all appliances is in the “OFF” position upon starting the generator. Only start the con-
nected appliance(s) when the GREEN Output Indicator Light is illuminated and the generator is
providing the necessary power to run the connected appliance(s).
Before connecting or reconnecting an appliance to the generator, check that it is in good order,
and that its electrical rating does not exceed that of the generator.
Reset power output after overload has been corrected by depressing the overload reset button.
LOW OIL ALARM SYSTEM:
This model is equipped with a Low Oil Alert System designed to avoid engine damage from
insufficient oil in the crankcase. The Low Oil Alarm System will stop the engine automatically
before the oil level in the crankcase drops below safe operating levels. This will cause the RED
Output Indicator Light to illuminate. Though the engine will stop running, the ignition switch will
remain in the “START” position. Turn to the “STOP” position.
STOPPING THE GENERATOR
Refer to Controls and Features section for diagram.
EMERGENCY SHUTDOWN
1. Push the on/off switch to the “off” position.
NORMAL SHUTDOWN
1. Unplug all electrical loads or turn the main breaker to the “OFF” position.
2. In order to stabilize internal equipment temperatures, allow the engine to run for 3- 5 minutes
under no load.
3. If the generator will not be in use for more than 7 days, turn the fuel valve to the “OFF”
position and allow the unit to run until the fuel in the carburetor is used and the engine shuts
itself off.
4. Turn the ignition switch to the “STOP” position.
5. Allow unit to cool to ambient temperature before storage or transportation.
6. Always transport the generator with the fuel valve in the “OFF” position. Failure to do so will
result in damage to the engine.
REMOTE SHUTDOWN
1. Press and hold the “OFF” button (marked with a padlock) on the remote start.
Summary of Contents for Energy Storm ESI-7000iER-EFI
Page 7: ...7 PRODUCT SPECIFICATIONS POWERED BY...
Page 8: ...8...
Page 12: ...12 CONTROLS AND FEATURES FUEL CAP FOLDING HANDLE LOCKING CASTER WHEELS CONTROL PANEL...
Page 44: ...44 WATTAGE CHART...
Page 45: ...45 WATTAGE CHART...
Page 46: ...46 WATTAGE CHART...
Page 51: ...51 APPENDIX...
Page 52: ...52 EXPLODED VIEW...
Page 53: ...53...
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57 NOTES...
Page 58: ...58...
Page 59: ...59...
Page 60: ......