Automotive Type Electronic 

Fuel Injection System

This generator has a computer-controlled fuel and ignition system. An on-board 
computer, referred to in this manual as an ECU (Engine Control Unit) utilizes a 
series of virtual maps (lookup tables) that provide values for various aspects of 
engine performance. The ECU analyzes data provided through the various
engine sensors to determine the best combination of values from these lookup 
tables to provide optimum performance. This is communicated to the generator 
components through the use of digital signals. This is in contrast to non-
computer-controlled ignition systems that rely on mechanical feedback, and 
sometimes vacuum, to control the motion of the various components.

This generator is equipped with an Electronic Fuel Injection (EFI) system, which 

provides increased efficiency over carbureted fuel systems. In a carbureted fuel 

system, the fuel and air are mixed in a carburetor that relies on a mechanical 
choke system controlling the rate of air intake to maintain the vacuum necessary 
to mix the fuel with air for combustion.

In a fuel injection system, the ECU calculates and adjusts the fuel mixture
directly, based on real-time feedback, allowing for greater fuel and emissions 

efficiency. The ECU also controls the timing for the spark plug, dynamically

controlling the speed of the engine depending on requirements for power
generation.

When there is a problem reported by a generator component (such as an engine 
sensor), the ECU stores a fault code for it. These fault codes can be read in the 

Wattage (P) field of the digital display, and then used to identify the issue and 

correct it. For more information on fault codes and how to access them, refer to 
the Fault codes section of this manual. For more information on the digital
display and its use, refer to the Digital display section of this manual.

Summary of Contents for Energy Storm ESI-7000iER-EFI

Page 1: ...Model ESI 7000iER EFI Please read this manual carefully before operating your new inverter generator CA in the model number designated California Compliant by CARB 9 1 2016...

Page 2: ...HERE MODEL ___________________________________ ENGINE ID _______________________________ DATE OF PURCHASE _______________________ PURCHASE LOCATION _____________________ CA INDICATES THIS UNIT IS CAR...

Page 3: ...questions a renter borrower might have Only Trained Adults should set up and operate this equip ment DO NOT LET CHILDREN OPERATE THIS EQUIPMENT Always wear safety apparel when operating this equipmen...

Page 4: ...pors or contact with skin may be hazardous Fire Explosion Engine sparking can ignite fuel or other flammable liquids or vapors in the vicinity Hot exhaust from engine can ignite combustible materials...

Page 5: ...peration of the equipment If you have any questions visit www lifanpowerusa com or call 1 866 471 7464 Option 2 Warranty and Service TABLE OF CONTENTS Preface 6 Operation of Generator 27 Storing The U...

Page 6: ...Keep this Owner s Manual for assistance in the future such as proper maintenance schedules and tips to prolong the life and effective use of your unit If you require assistance please visit our websit...

Page 7: ...7 PRODUCT SPECIFICATIONS POWERED BY...

Page 8: ...8...

Page 9: ...space for fuel expansion WHEN TRANSPORTING OR REPAIRING EQUIPMENT Transport inverter generator with the fuel valve in the off position Repair inverter generator with the fuel tank empty or the fuel va...

Page 10: ...d purposes The dealer or customer helpline 1 866 471 7464 can instruct you on intended uses Inverter generator must be placed on a level surface Do NOT expose inverter generator to extreme conditions...

Page 11: ...iency over carbureted fuel systems In a carbureted fuel system the fuel and air are mixed in a carburetor that relies on a mechanical choke system controlling the rate of air intake to maintain the va...

Page 12: ...12 CONTROLS AND FEATURES FUEL CAP FOLDING HANDLE LOCKING CASTER WHEELS CONTROL PANEL...

Page 13: ...13 LOCKING CASTER WHEELS EXHAUST PORT CONTROLS AND FEATURES FUEL LEVEL METER FUEL CAP CONTROL PANEL LOCKING CASTER WHEELS ACCESS PANEL...

Page 14: ...14 CONTROLS AND FEATURES LOCKING CASTER WHEELS FOLDING HANDLE ACCESS PANEL remove for oil fill drain access starter access etc...

Page 15: ...15 CONTROLS AND FEATURES LOCKING CASTER WHEELS FOLDING HANDLE ACCESS PANEL remove for maintenance of air cleaner element spark plug valve adjustment etc...

Page 16: ...Generator Accessory Kit 1 x Spark Plug Removal Tool 1 x Oil Drain Tube 1 x 12 Volt Power Cord with Plug Alligator Clips 1 x NEMA14 30 Male Twist Lock Plug 1 x RV Adapter Plug for 120 Volt 30amp Servic...

Page 17: ...lease visit our website www lifanpowerusa com or call 1 866 471 7464 between the hours of 9am 5pm Monday Friday UNPACKING THE GENERATOR 1 Set the Carton on a Flat Rigid Surface 2 Remove All Contents f...

Page 18: ...el Refer to Controls and Features section 3 Clean area around Oil Hole Dipstick Plug Unscrew Oil Hole Dipstick Plug 4 Use Supplied Funnel to Fill with appropriate type and amount of oil using Oil Fill...

Page 19: ...fuel tank Do NOT mix fuel with oil Fuel must have ethanol blend of 10 or less Pay close attention to the storage requirements of these fuels Do NOT overfill fuel tank 3 Install the fuel cap Rotate the...

Page 20: ...ontrols and Features section 2 Remove the Air Cleaner Case 3 Pull out the Air Cleaner Cartridge following the direction of the arrow 4 Check the cleanliness of the Air Cleaner Element 5 Clean Replace...

Page 21: ...copper grounding stake using copper electrical wire with a minimum diameter of 16 gauge GROUND TERMINAL BATTERY ASSEMBLY AND MAINTENANCE 1 Remove Left Access Panel 2 Insert battery into battery tray 3...

Page 22: ...engine will be shut off with either the remote fob the ignition key or by pressing the red STOP button on the control panel This man ual provides instructions notes and warnings dealing with each of t...

Page 23: ...enance door or you can simply check the voltage through the battery charge receptacle on the control panel This receptacle is connected directly to the battery so it can be used without the generator...

Page 24: ...ed outdoors only The total wattage of all appliances connected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit T...

Page 25: ...ted wattage for start up It is normal for the run time indicator to have 1 2 hours on the meter from the factory for testing and quality assurance inspections This generator uses a system ground which...

Page 26: ...t switch on the control panel in the ON position CAUTION Leaving the remote start switch in the ON position for more than six hours without operation will result in a dead battery and the inability to...

Page 27: ...Volt receptacles 5 Only connects single phase 60 Hertz loads 6 DO NOT OVERLOAD THE GENERATOR FOLLOW THE PROVIDED GENERATOR WATTAGE REFERENCE WORKSHEET TO DETERMINE THE RUNNING AND STARTING WATTAGE OF...

Page 28: ...ne With an inverter failure each of the following three symptoms will be present The ECU will draw the engine down to idling speed The digital display will indicate zero 0 Volts The 120 V receptacles...

Page 29: ...gine automatically before the oil level in the crankcase drops below safe operating levels This will cause the RED Output Indicator Light to illuminate Though the engine will stop running the ignition...

Page 30: ...rn the ignition switch to the STOP position 4 Drain the engine oil in accordance with the Oil Change Procedures in this Owner s Manual s Maintenance section Do NOT re fill with oil until ready to use...

Page 31: ...31 MAINTENANCE NOTE Refer to Following Procedures for Proper Method to Perform Maintenance MAINTENANCE SCHEDULE...

Page 32: ...drains only discard in an approved manner Check with your local authorities to determine the regulations in your area WARNING AVOID SPLASHING OF HOT OIL IT CAN BURN YOU AND CAUSE SEVERE INJURY 5 Afte...

Page 33: ...e 3 Pull out the Air Cleaner cartridge following the direction of the arrow 4 Check the Air Cleaner Element for cleanliness If needed clean replace Air Cleaner Element 5 Reinstall Air Cleaner Element...

Page 34: ...ANCE Refer to Controls and Features section for diagram NOTE Periodically you can get sediment or trash in your Carburetor Bowl Use the following procedures to clean 1 Turn the fuel valve to the OFF P...

Page 35: ...u do not want to take off the grille This will not cause an issue unless you drop the arrester or the clamp or screws behind the grille Taking the grille off or leaving it on is a matter of your conve...

Page 36: ...r vehicle high temperatures inside could cause residual fuel to vaporize resulting in possible explosion WARNING LONG TERM STORAGE OF THE GENERATOR During long term storage the generator should be sec...

Page 37: ...rom the tank 5 Change the engine oil 6 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder 7 Crank the engine several revolutions to distribute the oil and then rei...

Page 38: ...shut off valve to off position run unit until fuel in fuel lines and carburetor has burned out of system 4 Check the fuel level to insure adequate fuel Add fuel if necessary 5 Remove and inspect the...

Page 39: ...urning data 3 Confirm that the appliance to be used is switched off before plugging into the control panel 4 Plug the appliance into the control panel LOW OIL ALARM SYSTEM The low oil alarm system is...

Page 40: ...recharge the battery before you can start the generator again Back charging the generator battery This generator battery can be back charged through the DC receptacle by the included battery trickle c...

Page 41: ...is started and attempt to start the generator with the key fob or the ignition switch a jump start may occur but it will likely trip the DC breaker It is recommended to connect external batteries to t...

Page 42: ...e for the generator output P Wattage power output for the generator T Run time Total generator run time since first start in hours FUEL Fuel level bar reading It is normal for the run time indicator t...

Page 43: ...Replace fuel injector or wiring harness P0262 Check connection to injector Replace fuel injector or wiring harness to injector Manifold Air Pressure Sensor P0107 Short circuit Replace MAP sensor P0108...

Page 44: ...44 WATTAGE CHART...

Page 45: ...45 WATTAGE CHART...

Page 46: ...46 WATTAGE CHART...

Page 47: ...rsal motors which do not draw a heavy starting load drills small saws blenders etc require very little extra current for starting When listing items that use motors take them in the order of highest t...

Page 48: ...ied Warranty Registration Card must be complet ed and on file with American Warranty Service at the supplied address at the time that any warranty claim is made The Warranty Registration Card must be...

Page 49: ...to you call Lifan s automated phone at 1 866 471 4764 Option 2 Should you require assistance or have questions concerning Lifan Power USA Warranty Statement you can contact us through the web at www l...

Page 50: ...this paragraph and stipulates that the State and Federal courts located in the County of Crawford State of Arkansas shall have in person jurisdiction and venue over each of them for the purpose of lit...

Page 51: ...51 APPENDIX...

Page 52: ...52 EXPLODED VIEW...

Page 53: ...53...

Page 54: ...54...

Page 55: ...55...

Page 56: ...56...

Page 57: ...57 NOTES...

Page 58: ...58...

Page 59: ...59...

Page 60: ......

Reviews: