10
250 VA LED & ALARM INDICATIONS
Condition
Green AC
Light (4)
Audible Alarm
Status
NORMAL/START UP
On after Beep
Single Beep, then Off
Operate
Start-Up Test Fail
On after Beep
Fast Beep for 15 Sec and then Off
Operate*
Input Frequency Mismatch with
Option Switch Setting
Input Voltage Below Threshold
Off
Continuous
Will Not Start
Overload/Short Circuit
Off
Continuous for 15 Sec and then Off
Will Not Start
NORMAL MODE
On
Off
Operate
Battery Test Fail
On
Fast Beep for 15 Sec and then Off
Operate
Overload/Short Circuit
Off
Continuous for 15 Sec and then Off
Shutdown
BACKUP MODE
Off
Slow Beep
Operate
Low Battery Alarm
Off
Fast Beep
Warn of Shutdown
Low Battery Shutdown
Overload/Short Circuit
Off
Continuous for 15 Sec and then Off
Shutdown
Utility Overvoltage
(transfer enabled)
Off
Slow Beep
Operate
*The UPS starts and repeats the battery test sequence every hour until the test is passed.
400/600 VA LED & ALARM INDICATIONS
Condition
Green AC
Light (4)
Amber
Battery
Light (2)
Red
Warning
Light (3)
Audible Alarm
Status
NORMAL/START UP
On
Flash Once &
then Off
Off
Single Beep and then
Off
Operate
Start-Up Test Fail
Off
Off
On
Continuous for 15
Sec and then Off
Will Not Start
Input Frequency Mismatch
with Option Switch Setting
Overload/Short Circuit
Off
On for 15
Sec and
then Off
Flash
Continuous for 15
Sec and then Off
Will Not Start
Input Voltage Below
Threshold
Off
Off
Flash
Continuous for 15
Sec and then Off
Will Not Start
NORMAL MODE
On
Off
Off
Off
Operate
Battery Test Fail
On
Off
On
N/A
Operate
Overpower
On
Off
Flash
Fast Beep
Alarm Only
Overload/Short Circuit
Off
On for 15
Sec & then
Off
Flash for 15
Sec & then
Off
Continuous for 15
Sec & then Off
Shutdown
Charger Fail
On
Off
On
Slow Beep
Alarm Only
BACKUP MODE
Off
On
Off
Slow Beep
Operate
Low Battery Alarm
Off
On
On
Fast Beep
Operate
Low Battery Shutdown
Off
On*
On*
Continuous for 15
Sec & then Off
Shutdown
Utility Undervoltage
Off
On
Off
Slow Beep
Operate
Utility Overvoltage
Off
On
Flash
Slow Beep
Operate
Overload/Short Circuit
SiteNet 1 Shutdown
Off
On*
Flash*
Continuous for 15
Sec & then Off
Shutdown
*If there is insufficient utility voltage, this indicator illuminates for 15 seconds then turns off to preserve the battery.