Electromagnetic Compatibility: This equipment complies with EMC Directive 89/336/EEC and
the published technical standards. Continued compliance requires installation in accordance
with these instructions and the use of manufacturer approved accessories only.

CAUTION:
Although your UPS has been designed and manufactured to assure personal safety,
improper use can result in electrical shock or fire.  To insure safety, please observe the
following rules:

ƒ

 

Turn off and unplug your UPS before cleaning.  Do not use liquid or aerosol cleaners.  A
dry cloth is recommended to remove dust from the surface of your UPS.

ƒ

 

Do not install or operate your UPS in or near water.

ƒ

 

Do not place UPS on an unstable cart, stand, or table.

ƒ

 

Do not place UPS under direct sunlight or close to heat emitting sources.

ƒ

 

Do not place UPS power cord in any area where it may get damaged by heavy objects.

ƒ

 

Follow all warnings and instructions marked on the UPS.  Do not attempt to service the
UPS, as it has no user-serviceable parts inside.  Refer all repairs to qualified service
personnel.

ATTENTION:
Turn off and unplug your UPS from the outlet and contact qualified service personnel if:

ƒ

 

The power cord or plug is damaged.

ƒ

 

Liquid has been spilled on the UPS.

ƒ

 

The fuse blows frequently.

ƒ

 

The UPS does not operate even when user follows the operating instructions.

CONDITIONS OF USE:
Your UPS provides conditioned power to connected equipment. Maximum load must not
exceed that shown on UPS rating label. If uncertain, consult your distributor or Liebert.

Placing magnetic storage media on top of the UPS may result in data corruption.

Summary of Contents for PowerSure Personal

Page 1: ...USER MANUAL 300 500 VA 230V POWERSURE PERSONAL...

Page 2: ...FOR OTHER APPLICATIONS Store in safe place if not required at this time 4 This UPS must be earthed at all times during operation Connect only to a mains supply socket outlet with an earth connection...

Page 3: ...cart stand or table Do not place UPS under direct sunlight or close to heat emitting sources Do not place UPS power cord in any area where it may get damaged by heavy objects Follow all warnings and i...

Page 4: ...ptible Power System UPS It provides conditioned power to microcomputers and other sensitive electronic equipment MAJOR COMPONENTS Mains Battery LED Warning LED Liebert R P er sonal Pow erSure TM Power...

Page 5: ...Per sonal Pow erSure TM Check for Damage Liebert R Per sonal Pow erSure TM Liebert R Per sonal Pow erSure TM 110 mm 0 40 C Press ON Button for 2 seconds Remove Plug from Unit and replace in UPS Plug U...

Page 6: ...ated green 6 Check the operation of your load equipment it should display normal operational conditions 7 If any function provides an abnormal condition refer to the trouble shooting guide later in th...

Page 7: ...inuous Beep UPS Failure Battery Mode Mode Green Red Alarm Indicates Back Up Flash Every 3 sec OFF Beep Every 3 sec UPS is on Battery UPS Fault Flash Every 3 sec ON Continuous Beep No Output Low Batter...

Page 8: ...voltage below threshold AC overvoltage Plug in power cord securely Replace fuse and restart UPS Call a qualified electrician Wait until voltage rises to appropriate level Voltage must be higher than...

Page 9: ...eral signals are provided on this port and are assigned as follows PIN ASSIGNMENT DESCRIPTION 1 Low Battery open collector 2 No connection 3 No connection 4 On Battery Mode Shutdown 5 12V DC 5 On Batt...

Page 10: ...t and pull fuse holder out to remove AC Inlet Fuse Holder Input Fuse Spare Fuse CAUTION Before changing the supply fuse turn off the UPS and unplug the input mains lead from the AC mains socket and fr...

Page 11: ...Utility and Battery Modes Overload Warning 15 25 W Overload Warning 20 45 W BATTERY PARAMETERS Type Valve regulated nonspillable lead acid Quantity x Voltage x Rating 1 x 12V x 4 5 Ah 1 x 12V x 7 0 Ah...

Page 12: ...ident abuse neglect negligence unauthorized modification alteration or repair use beyond rated capacity or improper installation maintenance application or use including without limitation use in a ma...

Page 13: ...e than 1000 kVA Integrated systems that provide both environmental and power protection in a single flexible package Monitoring and control on site or remote from systems of any size or location Servi...

Reviews: