11
230V SPECIFICATIONS
Model Number
PSP300-230
PSP500-230
Model Rating VA / W
300 / 180
500 / 300
DIMENSIONS: mm (in)
Unit
H x W x D
178 x 76 x 238
(7.0 x 3.0 x 9.4)
178 x 76 x 238
(7.0 x 3.0 x 9.4)
Shipping
H x W x D
270 x 110 x 312
(10.6 x 4.3 x 12.3)
270 x 110 x 312
(10.6 x 4.3 x 12.3)
WEIGHT: kg (lbs)
Unit
2.8 (6.2)
3.6 (8.0)
Shipping
3.5 (7.7)
4.3 (9.5)
INPUT AC PARAMETERS
Voltage Range without Battery
Operation
185 to 263 VAC
Low Line Transfer
185 VAC
High Line Transfer
263 VAC
Frequency
45-55 Hz or 54-66 Hz; auto sensing
Input Power Receptacle
EN60320/C14
OUTPUT AC PARAMETERS
Output Receptacles
(2) EN60320/C13 sockets, (2) detachable EN60320-2-2
Voltage (Battery Mode)
230 VAC + 5%
Output Current
1.3 A
2.1 A
Waveform (Battery Mode)
Stepped Sinewave
Frequency
50 Hz or 60 Hz; auto sensing
Overload Warning
(Utility and Battery Modes)
101 – 120%
Overload Shutdown
(Utility and Battery Modes)
Overload Warning
(15 – 25 W)
Overload Warning
(20 – 45 W)
BATTERY PARAMETERS
Type
Valve-regulated, nonspillable, lead acid
Quantity x Voltage x Rating
(1) x 12V x 4.5 Ah
(1) x 12V x 7.0 Ah
Approved Battery
Manufacturers:
CSB, Panasonic, BB Battery and Yuasa
Transfer Time
2 – 6 ms typical
At 25°C (77°F), resistive loading, with fully charged batteries:
> 4 minutes
Back-up Time:
Full load
Half load
12 minutes
Recharge Time
7-10 hours to 90% capacity, after full discharge into 100% resistive load
ENVIRONMENTAL
Operating Temperature
0° C to +40° C (+32° F to + 104° F)
Storage Temperature
-15° C to +50° C (+5° F to + 122° F)
Relative Humidity
0% to 90%, non-condensing
Operating Elevation
Up to 3000 m. (10,000 ft) at 35° C (95° F) without derating
Audible Noise
<40 dBA, at 1 metre
AGENCY
Safety
EN50091-1-1 TUV/GS listed, CE Compliance Mark
Surge
IEC 801-5, Level 3
ESD
IEC 801-2, Level 3, Criterion< 2
Susceptibility
IEC 801-3, Level 3, Criterion< 2
Electrical Fast Transient/Burst
IEC 801-4, Level 4, Criterion< 2
Emissions
EN50091-2, Class B
Transportation
ISTA Project 1A