WARNING

Although the Liebert

®

 GXT3

 has been designed and manufactured to ensure safety, 

improper use can result in electrical shock or fire. To ensure safety, observe the following 

precautions:
• Turn Off and isolate the Liebert GXT3 before cleaning it. Use only a soft cloth; never use 

liquid or aerosol cleaners.

• Never block or insert any objects into the ventilation holes or other openings of the UPS.
• Do not place the Liebert GXT3 power cord where it might be damaged.

!

CAUTION

• When installed in EU countries, the Liebert

®

 GXT3-10000T220

 is not intended to operate 

with isolated neutral (IT systems). Neutral connector must be present and connected to the 

UPS.

• Even with all buttons OFF (see 

4.2 - Control Panel

) the device (UPS) is

 not 

isolated from 

the utility. To isolate completely from the utility, the power cables must be disconnected.

• In case of interruption of the utility voltage, the integrated battery maintains the power 

supply to the user equipment.

• Lay all cables so that nobody can stand on them or trip over them. When connecting the 

UPS to the power supply, follow the instructions in 

3.0 - Installation

.

• In emergencies (e.g., damaged case, controls or power cables, penetration of liquids or for-

eign matter), switch off the device and contact the appropriate customer service representa-

tive.

• Do not connect equipment that will overload the UPS (e.g., laser printers or vacuum clean-

ers) or demand DC-current (e.g., half-wave rectifiers).

• When cleaning the unit, follow the instructions in 

5.0 - Maintenance

.

• The sum of the leakage currents (protective conductor current) of the UPS and the con-

nected devices exceeds 3.5 mA for all ratings of the UPS. Ground (earth) connection is 

essential before connecting supply.

• Data transmission lines should not be connected or disconnected during a thunderstorm.
• Emergency Power Off (EPO) input is on the rear of the unit (see 

6.4 - Remote Emergency 

Power Off

 and 

3.6 - Terminal Blocks for UPS

). When this connection is open, the logic 

circuit will immediately shut down the UPS output.

• When installed in EU countries, an Emergency Switching Device (E.S.D.) must be fitted 

downstream of the UPS for the wiring installation safety to comply with the European Har-

monized Document HD384-4-46 S1.

• Maintenance bypass breaker is for the use of service personnel only. The breaker is on the 

rear of the unit. To operate the breaker, the captive screw must be loosened and the guard 

must be lifted out of position.

Summary of Contents for GXT3-10000T220

Page 1: ...More user manuals on ManualsBase com AC Power For Business Critical Continuity Liebert GXT3 10000T220 User Manual 10kVA 50 60 Hz 120 208 220V...

Page 2: ...More user manuals on ManualsBase com...

Page 3: ...nd Isolating Devices 8 3 4 External Electrical Connections 9 3 5 Connecting Utility and Load 9 3 6 Terminal Blocks for UPS 9 3 6 1 Input and Output Connection Requirements 10 3 7 Connecting Power Cabl...

Page 4: ...packing 6 Figure 4 Side view 9 Figure 5 Single source input supply input and output connections 9 Figure 6 Dual source input supply input and output connections 10 Figure 7 Hardwire terminals 10 Figur...

Page 5: ...do not electrically isolate internal parts Under no circumstances attempt to gain access internally due to the risk of electric shock or burn Do not continue to use the UPS if the front panel indicat...

Page 6: ...3 0 Installation In emergencies e g damaged case controls or power cables penetration of liquids or for eign matter switch off the device and contact the appropriate customer service representa tive D...

Page 7: ...nse The Liebert GXT3 series complies with the requirements of EMC Directive 2004 108 EC and the published technical standards Continued compliance requires installation in accordance with these instru...

Page 8: ...onic equipment operates best from sinewave power The liquid crystal display is used for controlling operation of the UPS as well as monitoring its status condition alarm status and history For ease of...

Page 9: ...wer UPS with Integrated Battery Liebert GXT3 10000T220 10000VA 90000W Battery Cabinet Liebert GXT3 240TBATTCE Control Panel Liquid Crystal Display Push Button Controls Ventilation Louvers Bypass Circu...

Page 10: ...00T220 near its installation site 2 Unlock all the snaps securing the shipping case to the shipping pallet 3 Lift the shipping case off the UPS 4 Remove the EPE packing cushions from around the Lieber...

Page 11: ...rea The area where the Liebert GXT3 10000T220 is to be placed must have sufficient space for installation procedures and for routine maintenance The UPS is narrow enough to pass through standard doorw...

Page 12: ...osition output power is available immediately upon application of AC input Table 2 Connection data Description Units Liebert GXT3 10000T220 Connector size AWG mm2 6 10 Max input current Arms 56 Input...

Page 13: ...0T220 is supplied by single phase utility connect the live phase to input L1 3 6 Terminal Blocks for UPS Figure 5 Single source input supply input and output connections WARNING Before removing electr...

Page 14: ...e in the building grounding electrode system If the grounding electrode conductor must be protected non metallic conduit is recommended If metal conduit must be used bond both ends of the conduit to t...

Page 15: ...iebert GXT3 10000T220 is supplied with each battery cabinet Open the breaker before making battery cable connections Plug one end of this cable into the UPS and the other end into the battery cabinet...

Page 16: ...with separate breakers utility and bypass rectifier booster inverter and charger electronic bypass 2 position Maintenance Bypass Breaker UPS and BYPASS integrated battery Figure 9 System block diagram...

Page 17: ...2 1 Controls and Messages Lighted LEDs UPS ON UPS is in normal online operation BYPASS Load is supplied by the utility via automatic bypass BATTERY Load is supported by the battery FAULT A problem has...

Page 18: ...Main Setup Control Contrast Set Battery Test Alarm Control Turn UPS On Off Status Log About Version Language Tag Number UPS Address DC Start Battery Test Interval Battery Pack Audible Alarm Output Vol...

Page 19: ...tup Menu Setting item Setting level 1 Audible alarm Disable Enable Output voltage 208 220 230 240V Battery pack 1 3 1 Battery Test interval DC start Disable Enable Tag Number 00000 99999 Language Engl...

Page 20: ...ry Test Battery Test Report Contrast Darker Lighter Battery Test Report Test in progress Test to Low Battery Test OK Cancel Battery test Test fail Battery Test report Test stop by user Test unknown 1...

Page 21: ...m of 4 fault events may be displayed in this window All fault displays include the nature of the fault event and the time it occurred the time is relative to the UPS operating time Display faults The...

Page 22: ...ontrol and press the Enter key 2 Select Turn UPS On Off and press the Enter key The LCD displays Turn UPS to BYPASS 3 Press the Enter key to switch off the inverter 4 Open any external circuit breaker...

Page 23: ...to Bypass mode 5 A single acoustic signal confirms the operation 6 Select Turn UPS On Off and press OK to place the UPS back in Normal Mode operation The UPS performs the test during Start up 4 8 2 Ba...

Page 24: ...ient temperature of 25 C but is also dependent on the frequency and duration of utility failures The BATTERY TEST see 4 8 2 Battery Test should be run periodically 6 to 12 months to ascertain the gene...

Page 25: ...Set 3 Remote Any Mode Shutdown can be performed using a switch connected to the pins in Set 3 and mounted at a remote location Activation of the Any Mode Shutdown will be logged as an event in the ev...

Page 26: ...rd Liebert IntelliSlot 485 Card The Liebert IntelliSlot SNMP Card provides SNMP monitoring and control of the UPS across the network The Liebert IntelliSlot Relay Card provides dry contact relay outpu...

Page 27: ...MultiLink software on four computers and coordinate shutdown in the event of a power failure The Liebert IntelliSlot Relay Card provides dry contact relay outputs for custom wired applications and de...

Page 28: ...mains voltage present Have utility mains inspected by a qualified technician UPS on LED does not illuminate when utility mains voltage present acoustic alarm active at intervals Input fuse defective o...

Page 29: ...0 seconds 105 130 1 minute Battery Parameters Type Valve regulated non spillable lead acid Quantity x V 20 x 12V Battery Mfr Part CSB HR1234R or Panasonic UP RW1245 Backup Time See Table 11 Recharge T...

Page 30: ...able 11 Environmental Operating Temp F C 32 to 80 0 to 27 Storage Temp 5 to 104 15 to 40 Transportation Temp F C 5 to 122 15 to 50 Relative Humidity 0 95 non condensing Operating Elevation Up to 3281...

Page 31: ...RATION To register for warranty protection Visit the Quick Links section of Liebert s Web site at http www liebert com Click on Product Warranty Registration and fill in the form If you have any quest...

Page 32: ...change without notice Liebert is a registered trademark of Liebert Corporation All names referred to are trademarks or registered trademarks of their respective owners Technical Support Service Web Si...

Reviews: