Liberty Pumps StormCell 442 Series Installation Manual Download Page 3

 

 

©Copyright 2018 Liberty Pumps Inc. All rights reserved. 

 

During construction, if the pump is installed before its power cord can be plugged in or direct wired, the power cord must be 
protected from the environment to prevent water from wicking through the cord end into the pump housing. If water enters the 
pump an electrical short can occur from the pump to its surroundings, which will energize the surroundings.   

 

 

RISK OF FIRE 

 

DO NOT use an extension cord to power the product. Extension cords can overload both the product and extension cord supply 
wires. Overloaded wires will get very hot and can catch on fire. 

 

This product requires a separate, properly fused and grounded branch circuit, sized for the voltage and amperage requirements of 
the pump, as noted on the nameplate. Overloaded branch circuit wires will get very hot and can catch on fire. 

 

NEVER  use  this  product  with  or  near  flammable  liquids.  If  the  rotating  elements  inside  this  pump  strike  any  foreign  object, 
sparks may occur. Sparks could ignite flammable liquids. 

 

DO NOT install this product in locations classified as hazardous or in explosive atmospheres as defined by any applicable safety 
code. 

 

Keep battery in a well ventilated area, away from sparks and open flames. Batteries generate flammable gasses both charging 
and discharging, which can explode or catch fire if ignited. 

 

 

RISK OF SERIOUS INJURY OR DEATH 

 

The pump must be installed in accordance with all applicable codes and ordinances.  

 

DO NOT allow children to play with the pump.  

 

DO NOT allow children, or any person who is unqualified to use the pump. Any person who is unaware of the dangers of this 
pump, or whom has not read this manual, can easily be injured by the pump.  

 

Wear adequate PPE when working on pumps or piping that have been exposed to wastewater. Sump and sewage pumps often 
handle materials which can transmit illness or disease upon contact with your skin and other tissues.  

 

DO NOT remove any tags or labels from the pump or its cord.  

 

ALWAYS, keep clear of the pump’s suction and discharge openings. The rotating elements of this pump are designed to draw 
in and pass foreign objects. 

 

NEVER, insert fingers into pump while it is energized. A stopped, energized pump may start without warning, via external test 
features built into the control system. 

 

Wear adequate PPE when working with batteries. Batteries contain strong acids that can cause severe burns to skin and soft 
tissues, if spilled. Prior to servicing your battery, refer to the battery manufacturers instruction manual or Safety Data Sheet 
(SDS) for a listing of proper PPE, proper handling techniques, and proper spill response, to minimize your risk of injury.  

 

DO NOT touch the finned top surface of the charging unit. This surface becomes hot during normal battery charging may burn 
exposed skin. Unplug the charger and allow it to cool prior to servicing. 

RISK OF ELECTRIC SHOCK - 

continued

 

 

 

Summary of Contents for StormCell 442 Series

Page 1: ...or future reference If manual becomes lost or damaged get a replacement manual at http www libertypumps com or contact Liberty Pumps Read manual before using pump Follow all safety instructions in man...

Page 2: ...ose the electrically live wires inside the power cord DO NOT bypass grounding wires The electrical power supply shall be located within the length limitations of the pump power cord and for below grad...

Page 3: ...ited RISK OF SERIOUS INJURY OR DEATH The pump must be installed in accordance with all applicable codes and ordinances DO NOT allow children to play with the pump DO NOT allow children or any person w...

Page 4: ...mation on installation 2 Introduction This manual was prepared to assist you in the correct installation operation and maintenance of your Liberty Pumps product Before Installation read the following...

Page 5: ...ded cable it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack You can use the cable provided with your charger for an example of a shielded connec...

Page 6: ...n larger sump pits when it is desirable to have the backup pump and primary pump on the same level This installation will require a tee a 90 elbow and two sections of piping A 90 street elbow is suppl...

Page 7: ...the 442 pump 5 Install the tee and pre glued nipple into the 442 pump discharge Tighten the hose clamp to 15 in lbs and mock up your 442 installation inside the sump pit without glue Ensure that the...

Page 8: ...to the charger and the user interface 5 Connect the charger battery leads to the battery or batteries in the case of a 442 25A ensuring that the connection is made first followed by the 6 Install a 9V...

Page 9: ...pump is activated Fault LED indicates a system fault Navigation Buttons scroll through notifications on UI LCD Alarm Silence Button Resets after 6 hours or if Silence button is pressed again StormCell...

Page 10: ...are no faults or notifi cations Explanation LCD home screen when system has faults and or notifications Number of message can be greater than 1 Explanation Standard LCD notification not directly indic...

Page 11: ...ve the 12V battery tested Probable Symptom Low battery alarm pump not running Check Check all wiring connections If AC power is out and the battery is ex hausted it will charge upon return of AC power...

Page 12: ...anty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been r...