6.   Operation, Repair, and Troubleshooting 

6-1 

CHARGER AND PUMP OPERATION 

The 442 backup pump will activate when the sump water level is high enough to actuate the “Pump On” float switch. The 442 back-
up pump run time depends on the Amp-hour capacity of the battery, the battery charge level, whether or not the charger has AC pow-
er, and the required equivalent vertical pumping distance.  

Extended periods of operation (power outage, primary pump failure, etc.) may exhaust the battery. If this occurs, the charger will 
recharge the battery when the period of extended operation ends. Recharge time from a “dead battery” state will be a minimum of 12 
hours. 

6-2 

INTERFACE LCD NOTIFICATIONS & MEANINGS

 

 

 

 

 

 

 

 

Explanation: 

Standard LCD home screen, shown when there are no faults or notifi-

cations. 

Explanation: 

LCD home screen when system has faults and / or notifications. 

Number of message can be greater than 1. 

Explanation: 

Standard LCD notification, not directly indicative of a problem. 

Denotes that 12V battery is being charged.  

Explanation: 

Standard LCD notification, will display after successful charging of 

12V battery.  

Explanation: 

Standard LCD notification, when 442 battery backup pump is 

running. 

Probable Symptom: 

High water condition in sump. 

Check: 

Verify high water condition. Check all wiring connections. Potential causes: 

failed (primary or secondary) pump, float switch hang-up, low or defective battery. 

Probable Symptom: 

Pump does not run. 

Check: 

All wiring connections and pump power cord. It is possible that the pump 

motor has failed. 

Check: 

Check all wiring connections and breaker for the circuit the battery charger 

is plugged in to. This notification will also display if the home has a power outage. 

INTERFACE LCD NOTIFICATIONS 

TROUBLESHOOTING/EXPLANATION 

Summary of Contents for StormCell 442 Series

Page 1: ...or future reference If manual becomes lost or damaged get a replacement manual at http www libertypumps com or contact Liberty Pumps Read manual before using pump Follow all safety instructions in man...

Page 2: ...ose the electrically live wires inside the power cord DO NOT bypass grounding wires The electrical power supply shall be located within the length limitations of the pump power cord and for below grad...

Page 3: ...ited RISK OF SERIOUS INJURY OR DEATH The pump must be installed in accordance with all applicable codes and ordinances DO NOT allow children to play with the pump DO NOT allow children or any person w...

Page 4: ...mation on installation 2 Introduction This manual was prepared to assist you in the correct installation operation and maintenance of your Liberty Pumps product Before Installation read the following...

Page 5: ...ded cable it should have a metal wrap around the outside of the connector that makes contact with the Ethernet jack You can use the cable provided with your charger for an example of a shielded connec...

Page 6: ...n larger sump pits when it is desirable to have the backup pump and primary pump on the same level This installation will require a tee a 90 elbow and two sections of piping A 90 street elbow is suppl...

Page 7: ...the 442 pump 5 Install the tee and pre glued nipple into the 442 pump discharge Tighten the hose clamp to 15 in lbs and mock up your 442 installation inside the sump pit without glue Ensure that the...

Page 8: ...to the charger and the user interface 5 Connect the charger battery leads to the battery or batteries in the case of a 442 25A ensuring that the connection is made first followed by the 6 Install a 9V...

Page 9: ...pump is activated Fault LED indicates a system fault Navigation Buttons scroll through notifications on UI LCD Alarm Silence Button Resets after 6 hours or if Silence button is pressed again StormCell...

Page 10: ...are no faults or notifi cations Explanation LCD home screen when system has faults and or notifications Number of message can be greater than 1 Explanation Standard LCD notification not directly indic...

Page 11: ...ve the 12V battery tested Probable Symptom Low battery alarm pump not running Check Check all wiring connections If AC power is out and the battery is ex hausted it will charge upon return of AC power...

Page 12: ...anty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been r...

Reviews: