Liberty Pumps ProVore PRG101AV Installation Manual Download Page 6

 

      ©Copyright 2015 Liberty Pumps Inc.    All rights reserved  

- 6 - 

Direct Wiring of 115V or 230V,  

Single Phase, Automatic Pumps 

 

TEMPORARY

 

MANUAL

 

OPERATION

 

DO!

 

DON’T!

 

Fig. 4  Piggyback plug installation.

 

 

All  "A"  models

  (automatic  pumps)  come  factory-equipped 

with a float switch mounted to the pump.  These models come 

with  two  cords  -  one  to  the  float  switch  and  the  other  to  the 

pump motor.  The switch cord has a series (piggyback) plug 

enabling the pump (motor) cord to be plugged into the back of 

it (see Fig. 4).  The purpose of this design is to allow manual 

operation  of  the  pump.  Note,  on  /  off  operation  of  the  pump 

must be controlled by the circuit breaker.  

For automatic operation

 using Liberty's supplied switch, the two cords should be interconnected and plugged 

into a separately fused, grounded outlet of proper amp capacity for your selected pump model.  (See Section 1, 

General Information, or the pump nameplate for electrical specifications of your model.)  Both cords are equipped 

with 3-prong plugs and must be plugged into a properly grounded 3-wire receptacle.  DO NOT REMOVE THE 

GROUND PRONGS.   
In  the  event  of  switch  failure,  the  pump  cord  can  be  separated  and  plugged  into  the  electrical  outlet,  directly 

bypassing the switch. For 115V and 230V single phase pumps should only be operated without the float switch by 

using the circuit breaker or panel disconnect.  Do not let the pump run dry. 
The turn-on level of automatic "A" models is approximately 12" to 16" above the bottom of the basin.  The turn-off 

level is approximately 6" above the bottom of the basin.  Other pumping differentials may be obtained by tethering 

the switch cord to the discharge pipe.  NOTE:  A minimum cord length of 3.5" from the tether point to the top 

surface of the float is required for proper switch operation.  If using a differential other than the factory setting, be 

sure when the pump shuts off at least 6" of fluid is left in the basin so the impeller remains submerged. 
Vertical switch models have pumping differentials pre-set by a rubber stopper placed on the float rod. To reset the 

pumping differential, slide the stopper to the required height to set the off position. This height Is approximately 2” 

from the bottom of the float rod, or high enough that the float does not have the potential to hang up on the pump 

or discharge. 

 

PRG Series pump models with an "M" designation

 are manual models with no switch.  They are intended to 

be run using an approved liquid level control or approved motor control with correct rating that matches motor 

input in full load amperes.  3-phase models require the use of an approved motor control that matches motor input 

in full load amperes with overload element(s) selected or adjusted in accordance with control instructions. 

 

Automatic operation with optional control devices:

 If the pump(s) are to be operated by either a simplex or 

duplex control panel, or other optional control device, follow the installation instructions provided with your specific 

control and make the power connections per those instructions.  If necessary, certain models may be run without 

a separate control.  230V single-phase pumps should only be operated without the float switch by using the circuit 

breaker or panel disconnect.  Do not let the pump run dry. 

 

ProVore

®

 "A" and "M" models: 

 If the pump is to be wired directly into a control device or junction box, and it is 

necessary to remove the plugs, have a certified electrician do the wiring in accordance with the National Electric 

Code and applicable local codes.  See Fig. 5 for direct wire installation of single phase, automatic pumps. 

 

In  230V  installations, 

one  side  on  the  line 

going  to  the  pump  is 

always  “hot”,  whether 

the float switch is on or 

off.  To avoid hazards, 

install  a  double  pole 

disconnect  near  the 

pump installation. 

 
 
 
 

Figure C

 – Direct wiring of 115V or 208-230V, single 

phase, automatic pumps. 

Summary of Contents for ProVore PRG101AV

Page 1: ...se Automatic Switch 25 Power cord PRG102M 1 hp 230V 1 phase 10 cord PRG102M 2 1 hp 230V 1 phase 25 cord Do not throw away or lose this manual Contents General Information Introduction Mechanical Insta...

Page 2: ...en working on a used pump or piping Never enter a pump basin after it has been used Sewage and effluent can emit several gases which are poisonous Keep clear of suction and discharge openings To preve...

Page 3: ...l type cartridge seal with two silicon carbide faces 4 The impeller and volute are designed for efficient flow characteristics and clog free operation The hardened cutters grind solids and fibrous mat...

Page 4: ...ending on local codes and the number of fixture units entering the system Check with the local authorities or contact Liberty Pumps if you are unsure of the proper basin size Installation should be at...

Page 5: ...ent plug To reduce the risk of electric shock be certain that the grounding conductor is connected only to a properly grounded control panel or if equipped with a grounding type plug that it is connec...

Page 6: ...differential other than the factory setting be sure when the pump shuts off at least 6 of fluid is left in the basin so the impeller remains submerged Vertical switch models have pumping differentials...

Page 7: ...proper electrical connection Prior to pump installation ensure that the float mounting screw is installed tightly FLOAT SEQUENCE PIGGY BACK SWITCH AUTOMATIC MODELS 1 As the liquid level in the wet wel...

Page 8: ...set 3 5 tether 1 Float System vertical float Pump Off Factory set 2 from bottom of float rod Pump On Maximum travel on float rod SIMPLEX PUMP STATION 3 Float System Pump Off Level to top of motor hou...

Page 9: ...IFY THE LIBERTY PRODUCT SERVICE DEPARTMENT IMMEDIATELY DO NOT SWITCH THE POWER SUPPLY LEADS DO NOT OPERATE THE PUMP ALWAYS ENSURE THAT THE PUMP IS FREE OF WIRES OR OTHER OBSTRUCTIONS THAT MAY CAUSE HA...

Page 10: ...ischarge line passes through or into cold areas Check valve is stuck closed or installed backwards Remove check valve s and examine for freedom of operation and proper installation Gate or ball valve...

Page 11: ...s Warranty if the product has not been properly installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has...

Page 12: ...Copyright 2015 Liberty Pumps Inc All rights reserved 12 This page intentionally left blank 7000 Apple Tree Avenue Bergen NY 14416 Phone 800 543 2550 Fax 585 494 1839 www libertypumps com...

Page 13: ...G102A 2 1 hp 230 V monof sica interruptor autom tico cord n el ctrico de 25 pies PRG102M 1 hp 230 V monof sica cord n el ctrico de 10 pies PRG102M 2 1 hp 230 V monof sica cord n el ctrico de 25 pies N...

Page 14: ...e bomba despu s que haya sido usada Los sistemas de efluentes y de aguas residuales pueden emitir diferentes tipos de gases t xicos Mant ngase alejado de la entrada de succi n y de la salida de descar...

Page 15: ...arburo de silicio 4 El rotor y la voluta est n dise ados para producir un caudal ptimo y funcionar sin obstrucciones Los discos endurecidos trituran la materia s lida y fibrosa hasta convertirla en pa...

Page 16: ...didad suficiente como para que todas las ca er as queden por debajo de la l nea de penetraci n de la helada Si esto no fuera posible desmonte la v lvula de retenci n y modifique el tama o de la cubeta...

Page 17: ...tiene que estar conectado debidamente a un panel de control a tierra o si cuenta con un enchufe a tierra tendr que enchufarse a un tomacorriente conectado a tierra NO derive los cables de puesta a tie...

Page 18: ...les vienen con diferenciales de bombeo configurados de f brica por un tap n de caucho en la barra del flotador Para reiniciar el diferencial de bombeo deslice el tap n a la altura necesaria para estab...

Page 19: ...SECUENCIA DEL FLOTADOR INTERRUPTOR EN CASCADA MODELOS AUTOM TICOS 1 El flotador va subiendo a medida que sube el nivel del sumidero inundado con lo que cierra el interruptor Esto hace arrancar la bomb...

Page 20: ...m 2 pulg del fondo de la barra del flotador Bomba encendida recorrido m ximo en barra del flotador ESTACI N DE BOMBA SIMPLE Sistema de 3 flotadores Bomba apagada nivel hasta parte superior del chasis...

Page 21: ...TY INMEDIATAMENTE NO CAMBIE LOS HILOS DE ALIMENTACI N NO ENCIENDA LA BOMBA COMPRUEBE SIEMPRE QUE NO HAYA CABLES SUELTOS Y OTRAS OBSTRUCCIONES QUE PUDIERAN CAUSAR LESIONES PERSONALES O DESPERFECTOS MAN...

Page 22: ...e haya quedado cerrada o est instalada al rev s Saque las v lvulas de retenci n y aseg rese de que funcionan sin impedimentos y que hayan sido instaladas correctamente La v lvula de compuerta o la de...

Page 23: ...ha sido instalado correctamente si ha sido desmontado modificado abusado o forzado si el cable el ctrico se ha cortado da ado o empalmado si se redujo el tama o del desag e de la bomba si la bomba se...

Page 24: ...Copyright 2015 Liberty Pumps Inc Todos los derechos reservados 12 Esta p gina se ha dejado en blanco intencionalmente...

Page 25: ...m 10 pi PRG102A 2 1 HP 230 V monophas e interrupteur automatique cordon d alimentation de 7 6 m 25 pi PRG102M 1 HP 230 V monophas e cordon d alimentation de 3 m 10 pi PRG102M 2 1 HP 230 V monophas e...

Page 26: ...s le r servoir de pompage apr s qu il a servi Les gouts et effluents peuvent mettre des gaz toxiques Demeurer l cart des orifices d aspiration et d vacuation Afin de pr venir les blessures ne jamais i...

Page 27: ...s pouvant tre pomp es de mani re s curitaire au travers des conduits de petit diam tre 5 Pour les syst mes d gout consulter les codes de plomberie relativement aux exigences relatives la ventilation d...

Page 28: ...retour et corriger la taille du bassin et ou ajuster le diff rentiel du compartiment pour recevoir le volume suppl mentaire de refoulement d eau A Excavation Creuser le trou le plus petit possible ave...

Page 29: ...neau de commande correctement mis la terre ou s il est muni d une fiche avec mise la terre qu elle est correctement mise la terre NE PAS d vier les fils de mise la terre ou retirer la broche de mise l...

Page 30: ...pr d finis par un bouchon en caoutchouc plac sur la tige du flotteur Pour r initialiser l intervalle de pompage faites glisser le bouchon la hauteur requise pour choisir la position Arr t Cette hauteu...

Page 31: ...QUENCE DU FLOTTEUR SIAMOIS MOD LES AUTOMATIQUES 1 mesure que le niveau de liquide monte dans la b che d aspiration le flotteur monte et ferme l interrupteur Cela fait d marrer la pompe 2 La pompe tou...

Page 32: ...partir du bas de la tige du flotteur Pompe en marche d placement maximal sur la tige du flotteur STATION DE POMPAGE SIMPLE Syst me trois flotteurs Pompe arr t e niveau du sommet du bo tier du moteur P...

Page 33: ...E PAS INVERSER LES BORNES D ALIMENTATION LECTRIQUE NE PAS FAIRE FONCTIONNER LA POMPE TOUJOURS S ASSURER QUE LA POMPE EST LIBRE DE TOUTE OBSTRUCTION PAR DES C BLES OU AUTRES L MENTS POUVANT PROVOQUER D...

Page 34: ...la canalisation d vacuation se trouve dans des zones froides ou les traverse Clapet antiretour bloqu en position ferm e ou incorrectement install Retirer tout clapet antiretour et v rifier qu il fonct...

Page 35: ...t correctement install s il a t d mont modifi soumis un usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pom...

Page 36: ...berty Pumps Inc 2015 Tous droits r serv s 12 Cette page a t laiss e blanche intentionnellement 7000 Apple Tree Avenue Bergen NY 14416 T l phone 800 543 2550 T l copieur 585 494 1839 www libertypumps c...

Reviews: