background image

16 | EN

Copyright © Liberty Pumps, Inc. 2020 All rights reserved.

5755000K

Warranty

 

 Liberty Pumps Wholesale Products Limited Warranty

Liberty Pumps, Inc. warrants that Liberty Pumps wholesale products are free from all factory defects in material and workmanship for a 

period of three (3) years from the date of purchase (excluding batteries). The date of purchase shall be determined by a dated sales 

receipt noting the model and serial number of the pump. The dated sales receipt must accompany the returned pump if the date of 

return is more than three years from the date of manufacture noted on the pump nameplate.
The manufacturer's sole obligation under this Warranty shall be limited to the repair or replacement of any parts found by the 

manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service 

center, and provided that none of the following warranty-voiding characteristics are evident:
The manufacturer shall not be liable under this Warranty if the product has not been properly installed, operated, or maintained per 

manufacturer instructions; if it has been disassembled, modified, abused, or tampered with; if the electrical cord has been cut, damaged, 

or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating; 

if the pump has been used in water containing sand, lime, cement, gravel, or other abrasives; if the product has been used to pump 

chemicals, grease, or hydrocarbons; if a non-submersible motor has been subjected to moisture; or if the label bearing the model and 

serial number has been removed.
Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect, 

incidental, and consequential damages, including costs of removal, reinstallation or transportation.

There is no other express warranty. All implied warranties, including those of merchantability and fitness for a particular purpose, are 

limited to three years from the date of purchase. This Warranty contains the exclusive remedy of the purchaser, and, where 

permitted, liability for consequential or incidental damages under any and all warranties are excluded.

 

7000 Apple Tree Avenue

Bergen, NY 14416

ph: 800-543-2550

fax: 585-494-1839

www.LibertyPumps.com

Summary of Contents for Ascent II-ESW

Page 1: ...Pumps com or contact Liberty Pumps at 800 543 2550 Retain dated sales receipt for warranty Serial Mfg Date Install Date Installation Manual 5755000K Copyright Liberty Pumps Inc 2020 All rights reserve...

Page 2: ...ndoor dry location use only Serious injury or death could result Do not use an extension cord to power the product Extension cords can overload both the product and extension cord supply wires Overloa...

Page 3: ...controls and must be protected from direct water exposure during installation and use Sanitary fixtures connected to the macerating system must be located on the same floor level Introduction Before i...

Page 4: ...ng toilet and needs no special maintenance with normal use Any regular bathtub up to 100 gallons or shower can be used When installing these fixtures build a 6 inch high platform for the fixture to be...

Page 5: ...ceptacle is accessible under the left decorative cover Do not install battery until the unit has been installed connected and ready for operation Auxiliary Inlets The macerator unit is equipped with t...

Page 6: ...left side When roughing in allow for the macerator Discharge Never discharge directly into an open drain fixture manhole or rainwater drainpipe It is illegal as it constitutes a health hazard Only dir...

Page 7: ...e 40 PVC pipe is used for the discharge and runs horizontally for 1 ft then turns 90 and rises 5 ft vertical Then it travels horizontal with another 90 turn 3 turns in total and connects with the soil...

Page 8: ...tallation manual s provided with it Be careful when tightening fasteners as to not crack the porcelain Figure 4 Placement Options Figure 5 Toilet Connections 1 To mount the toilet to a concrete floor...

Page 9: ...or Sewer The discharge piping can be made from 3 4 or 1 diameter PVC pipe Use long turn bends and avoid elbows where possible The connection to the soil stack or sewer pipe must be made with an appro...

Page 10: ...scharge flange has an integrated check valve The valve is held in place by a support backing plate that is also connected to the discharge hose To access the check valve first remove the discharge fla...

Page 11: ...e and once engaged the base can be rotated counterclockwise until it is free Accessibility to Motorized Cartridge The motorized cartridge can be accessed through the access opening or removal of the m...

Page 12: ...acle GFCI are on Check condition of circuit breaker or fuse Ensure plug is not loose If the pumping unit thermal overload has activated it will take about 20 minutes to reset Decorative Covers Ensure...

Page 13: ...e may be blocked The piping must be cleaned Unit not vented correctly Unit must be vented properly to open air to allow water to enter the macerator tank Confirm vent is clear Do not use a quick vent...

Page 14: ...tor is either not plugged in supply breaker is turned off or GFCI receptacle has tripped Check electrical power source Control system in battery protection mode 1 Unplug macerator from receptacle 2 Re...

Page 15: ...over on page 10 General plumbing During the draining of the bathtub the alarm sounds and or water backs up into the toilet The inflow is greater than the macerator can handle A full port ball valve sh...

Page 16: ...operated or maintained per manufacturer instructions if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been...