Coding the transmitter with the
receiver
• Press the receiver’s
pushbutton for more
than 3 seconds. The indicator
light will start
flickering, release the pushbutton. The system is
in
configuration
mode.
• Press the
Reset
button during 3 seconds of
the transmitter.
The indicator
button will stop flickering, at
the end of 5 secondes.
The transmitter/receiver link is now established.
• Set time.
For clearing all transmission/reception links:
• Press the receiver’s pushbutton
for more
than 10 seconds. The indicator
light flickers
slowly, then more quickly.
• Press again the receiver’s pushbutton
more
than 3 seconds. The indicator
l
ight stops
flickering, all links have been cleared.
Adjusting the temperature set
Your thermostat controls 2 levels of temperatures:
•
Comfort
temperature: this is the temperature
level you want during the time you are present
(20°C for example).
•
Reduced
temperature: this is the temperature
you want during short absences or at night
(16°C for example).
We advise a difference of 4 °C (minimum) between
the
Comfort
and
Reduced
temperatures.
To change the Comfort temperature:
• In
Auto
mode, using
+
or
–
keys to modify the
set-point. Such modification is temporary (last
segment of bargraph flickers). On next program
step, the thermostat will operate on the usual
set-point.
• In
Comfort
mode, using
+
or
–
keys to modify
the set-point. Such modification is permanent.
To change the reduced temperature:
• In
Auto
mode, using
+
or
–
keys to modify the
set-point. Such modification is temporary (last
segment of bargraph flickers). On next program
step, the thermostat will operate on the usual
set-point.
• In
Reduced
mode, using
+
or
–
keys to modify
the set-point. Such modification is permanent.
The
Comfort
and
Reduced
temperatures can
be set from +5°C to +30°C in steps of 0.5°C.
When you adjust the
Comfort
and
Reduced
,
finished, after 5 seconds the thermostat automa-
tically displays the ambient temperature.
The current set temperature is permanently
displayed on the bargraph.
In the case of a temperature set-point, the last
segment of the bargraph flickers.
Programmation
To programme your heating you have available 3
prerecorded and modifiable programs:
P1
,
P2
and
P3
:
•
P1: Comfort
from 6h00 to 23h00.
Reduced
from 23h00 to 6h00.
•
P2: Comfort
from 6h00 to 8h30
and from 17h30 to 23h00.
Reduced
from 8h30 to 17h30
and from 23h00 to 6h00.
•
P3: Comfort
from 6h00 to 8h30, from 11h00 to
14h00 and from 17h30 to 23h00.
Reduced
from 8h30 to 11h30, from 14h00
to 17h30 and from 23h00 to 6h00.
• The first programming time schedule appears and
flickers. The cursor
under the symbol
indi-
cates the start time of a
Comfort
temperature
cycle.
• Scroll the various programming schedules by
pressing the
OK
key repeatedly.
• When the cursor
is under the symbol ,
it indicates the start time of a
Reduced
temperature cycle.
• When the schedule of the last cycle is confirmed
using the
OK
key, the thermostat is set to
Auto
mode and displays the room temperature.
• Using keys
+
or
–
, modify the start time of each
cycle as required (maintain key down for a
longer time to make minutes scroll faster).
In
Auto
mode the thermostat manages auto-
matically the desired temperature (
Comfort
or
Reduced
) according to the program set.
On startup,
P1
program is active in
Auto
.
To select the desired program:
• In
Auto
mode, press
Prog
key to display the
desired program (P1, P2 or P3).
• The displayed program flickers (for example P1).
• Press
OK
to confirm.
Permanent override
This mode transforms the appliance into a simple
electronic thermostat.
It no longer takes the timed program into
account.
• Press the
Mode
key and position the operating
pointer
, under the symbol
or
(
Comfort
or
Reduced
) as you choose.
• To change the
Confort
or
Réduit
, use the
+
and
–
keys.
• The set temperature is displayed instead of the
ambient temperature and flashes, then the
thermostat returns to display of the ambient
temperature.
Temporary override
This mode allows to modify the temperature set-
point temporarily during a program step.
• In
Auto
mode, press the
+
or
–
keys to modify
the temperature set-point.
• The last segment of the bargraph then flickers
until the next program step.
On the next program step, the defined temperature
set-points are again active.
Troubleshootings
•
The heating does not start:
- receiver’s power supply is cut off (the
indicator
light is off). Check fuse and circuit
breaker.
- re-install receiver.
•
The system does not start or does not
stop:
- the receiver or transmitter is disturbed by
radio transmission (radio ham, TV monitor,
cellular phone re-transmitter, etc.): attempt to
remove the source of disturbance.
- Receiver is outside of transmitter’s range, move
transmitter closer to receiver.
In case of persistent problem, call on your
electrician.
Technical specifications
Supply:
2 batteries type 1,5V LR03
Lifetime:
about 1 year
Power reserve:
max. 20 sec.
Transmission frequency:
433.92 Mhz
Transmitter duty cycle:
10%
Range of setting of
Comfort
and
Reduced
temperatures:
5°C to 30°C
Range of display of ambient temperature;
0°C to 40°C
Transmission distance: 100 metres in a clear field
Operating temperature:
0°C to +40°C
Storage temperature:
-20°C to +60°C
Hygrometry:
90% max to 25°C
Degree protection:
IP 31
Class Insulation:
III
Dimensions: 120 x 80 x 35
mm
IK:
04
Standards:
NFC – 73251, NF EN 60730-1,
EN 300 220-1 V2.1.1, EN 300 220-2 V2.1.1
Made in France
Usable in all Europe and Switzerland
4
6h
23h
6h
8h30
17h30
23h
6h 8h30 11h30 14h
17h30
23h