LGMG North America Inc.
Maintenance Manual
12
Overservicing may cause dirt to enter the
engine causing premature wear. Use the dust
indicator as a guide on when to service.
1)
Open the hooking clip.
2)
Remove the filter cover (2) and screw off
the filter element (4).
3)
Filter element (4): For slight contamination,
purge with dry compressed air (maximum
205 Kpa) from inside to outside for cleaning
(general cleaning times are no more than 5
times);
Replace it in case of serious contamination.
Replacement of the Safety Filter Tube of the
Air Filter
△
!
Never clean the safety filter tube (3).
1)
Screw off the Primary element (4) and the
Secondary element (3).
2)
Install the new Secondary element.
3)
Install the filter element (4), place the outer
cover (2) and fix it with the hooking clip.
1.14
Check
for
Coolant
Liquid Level
Check the coolant liquid level every 8 hours or
every day.
△
!
The coolant at high temperature
has the risk of scald.
The cooling system is under pressure! The
cover can only be opened in the cooling state.
Coolant must have a specified concentration of
cooling system protectant!
Please observe the safety regulations for
coolant and relevant local regulations.
Dispose of the spilled coolant as specified,
without leaving it on the ground.
Never run the engine without coolant, even if it's
a very short time.
1)
Carefully open the cover for the cooling
system.
2)
The coolant liquid level shall always be
between min and max! Fill up to the
maximum liquid level if necessary.
1.15 Filling or Replacement
of Engine Coolant
Replace it every 2,000 hours or two years.
△
!
The coolant at high temperature
has the risk of scald.
The cooling system is under pressure! The
cover can only be opened in the cooling state.
Coolant must have a specified concentration of
cooling system protectant!
Please observe the safety regulations for
coolant and relevant local regulations.
Dispose of the spilled coolant as specified,
without leaving it on the ground.
Never run the engine without coolant, even if it's
a very short time.
Draining of the Cooling System
1)
Carefully open the cooler cover.
2)
Place the receiving container under the
coolant interface.
3)
Drain the coolant.
4)
Reconnect
and
tighten
the
coolant
interface.
5)
Close the cooler cover.
Filling of the Coolant
1) Carefully open the cover for the cooling
system.
2) Loosen the cooler exhaust bolts that may
be present.
3) Fill the coolant to max or the filling limit
position.
4) Open the possible heater and switch to the
maximum gear, to fill the heating circuit and
exhaust.
5) Close the cooler cover.
Summary of Contents for T65J
Page 2: ...This page left blank intentionally...
Page 6: ...LGMG North America Inc Maintenance Manual IV This page left blank intentionally...
Page 7: ...LGMG North America Inc Maintenance Manual 1 Chapter 1 Maintenance...
Page 8: ...LGMG North America Inc Maintenance Manual 2...
Page 30: ...LGMG North America Inc Maintenance Manual 24...
Page 31: ...LGMG North America Inc Maintenance Manual 25 Chapter 2 Schematics...
Page 32: ...LGMG North America Inc Maintenance Manual 26...
Page 33: ...LGMG North America Inc Maintenance Manual 27 Electric schematic T65J...
Page 34: ...LGMG North America Inc Maintenance Manual 28 Electric schematic T85J...
Page 35: ...LGMG North America Inc Maintenance Manual 29 Hydraulic schematic T65J...
Page 36: ...LGMG North America Inc Maintenance Manual 30 Hydraulic schematic T85J...
Page 37: ...31...