8-1. BEFORE SVC CHECKING
¡Æ
Be careful of electric shock or disconnecting the parts while trouble shooting.
¡Æ
Voltage of each terminal in 220-240V~ and DC while applying an electric current.
8-2. QC TEST MODE.
¤
Pressing Spin, and Temp button simultaneously.
¤Ł
Power supply ON with pressing upper two button. then buzzer sound twice.
¤Ø
Press the START/PAUSE button as follows.
¡a
Press the START/PAUSE button more 4 times until stop spinning
¡b
8-3. HOW TO KNOW THE WATER LEVEL FREQUENCY
ƒR
Press the Option and Spin button simultaneously.
ex) 241 : Water level frequency = 241
¡¿
10-1
§
=24.1
§
14
8. TROUBLE SHOOTING
The digits means water level frequency(10
-1
§
)
Pressing number of
£
START/PAUSE
£
button
Checking Point
Display Status
None
All lamps turn on
1 time
Clockwise spin(right)
Motor rpm(About 45)
2 times
Low speed Spin
Motor rpm(About 63~67)
3 times
High speed Spin
Motor rpm(About 79~85) : WD(M)-8070F(H)(B)
Motor rpm(About 100~106) : WD(M)-1070(5)F(H)(B)
Motor rpm(About 107~103) : WD(M)-1170(5)F(H)B
Motor rpm(About 114~120) : WD(M)-1270(5)F(H)B
Motor rpm(About 122~127) : WD(M)-1370(5)F(H)B
4 times
Inlet valve for pre-wash operation
Water level frequency(25~65)
5 times
Inlet valve for main-wash operation
Water level frequency(25~65)
Hot inlet valve in case of hot water fill
6 times
Inlet valve for main-wash operation
Water level frequency(25~65)
7 times
Counterclockwise spin(left)
Motor rpm(About 45)
8 times
A Heater is in operation for 3 sec.
Water Temperature
9 times
Draining pump operation
Water level frequency
10 times
Auto off operation