26
WASH HEATER TROUBLE
When checking the voltage between
connector the PWB assy(Main)during
whites washing ,Is the voltage
220 - 240V ?
Replace the PWB assy
(Main)
YES
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30 ?
Replace the heater assy
NO
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10 to 30 ?
Normal
NO
YES
RED
YELLOW
1
2
4
3
~
220 - 240V~
PWB ASSY(Main)
220-240V
NO
NO
YES
NO
YES
■
WD(M)-8070F(H)B, WD(M)-1070(5)F(H)B, WD(M)-1170(5)F(H)B, WD(M)-1270(5)F(H)B, WD(M)-1370(5)F(H)B
■
WD-8070F(H), WD-1070(5)F(H)
When checking the voltage between two
receptacles of the PWB assy(Power) during
washing.
Is the voltage 220-240V?
After power off, is the resistance between yellow
wire and red wire of
connector 10 to 30 ?
After power off, is the resistance of heater
10 to 30 ?
Replace the PWB assy
(Power)
Normal
Replace the heater assy