- 62 -
Note
Please check if all the components are working properly.
Part 8. Check whether electrical equipment is abnormal or not.(Gas dryer)
Component
Test Procedure
Check result
Remark
1. Outlet Thermostat (Cut off)
Check Top Marking: N85
Measure resistance of terminal to
terminal
①
Open at 185 ± 9˚F
(85 ± 5˚C)
Same shape as thermal cut off.
①
Resistance value
≒
∞
②
Resistance value ˂ 5Ω
•
Blower housing
- Safety
2. Thermistor
Measure resistance of terminal to
terminal
Temperature condition:
58˚F ~ 104˚F (10~40˚C)
Resistance value: 10Ω
•
Heater case Hi
limit
•
Electric type
3. Gas Valve
Measure resistance of the following
terminal
①
Valve 1 terminal
②
Valve 2 terminal
①
Resistance value 1.5k~2.5kΩ
②
Resistance value 1.5k~2.5kΩ
•
Gas type
4. Igniter 5318EL3001
Measure resistance from terminal
to terminal.
Resistance value
50~800Ω
(for 5318EL3001)
•
Gas type
5. Flame Detect
Measure resistance of terminal to
terminal
①
Open at 370˚F (Maximum)
②
Close at 320˚F
①
Resistance value
≒
∞
②
Resistance value ˂ 1Ω
•
Gas type
6. Outlet Thermostat (Auto reset)
Check Top Marking: N95
Measure resistance of terminal to
terminal
①
Open at 203 ± 41˚F (95 ± 5˚C)
②
Close at 159 ± 41˚F (70 ± 5˚C)
①
Resistance value
≒
∞
②
Continuity ˂ 1Ω
•
Gas type
•
Gas funnel
7. Outlet Thermostat (Manual reset)
Check Top Marking: N100
Measure resistance of terminal to
terminal
①
Open at 230 ± 41˚F
(110 ± 5˚C)
②
Manual reset
①
Resistance value
≒
∞
②
Continuity ˂ 1Ω
•
Gas type
•
Gas funnel
Summary of Contents for W3S1 Series
Page 13: ... 13 5 OPERATION 5 1 Control Panel Features WASHER W3S1CVK2 DRYER ...
Page 112: ...EXPLODED VIEW FULL ASSEMBLY WASHER DRYER DRYER WASHER Control Panel F1100 F112 F210 F113 EV ...
Page 121: ... 123 ELECTRIC DRYER GAS DRYER ...
Page 122: ... 124 ELECTRIC DRYER GAS DRYER ...
Page 123: ......
Page 124: ...P No MFL68588942 ...