background image

OWNER’S MANUAL

Please read this manual carefully before operating
your set and retain it for future reference.

P/NO : MFL37115811

www.lg.com

TYPE : POWER DISTRIBUTION INDICATOR 
MODELS : PQNUD1S00

ENGLISH

ITALIANO

ESPAÑOL

FRANÇAIS

DEUTSCH

CHINESE

Summary of Contents for V-net PQNUD1S00

Page 1: ...ase read this manual carefully before operating your set and retain it for future reference P NO MFL37115811 www lg com TYPE POWER DISTRIBUTION INDICATOR MODELS PQNUD1S00 ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH CHINESE ...

Page 2: ...tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they do ...

Page 3: ... material in vicinity of the product Donʼt disassemble repair and modify the product at your will Otherwise it may cause fire hazard and product trouble failure Or else it may cause fire hazard and electric shock Cautions for safety To prevent injury to the user or other people and property damage the following instructions must be followed Incorrect operation due to ignoring instruction will caus...

Page 4: ...Donʼt spill water into interior of the product Donʼt put heavy material upon electricity supply chord Donʼt put heavy material upon the product Otherwise it may cause electric shock and product failure Or else it may cause fire hazard and electric shock Or else it may cause product trouble failure Always request to our Service Center or installation expert agency in such case as the product has be...

Page 5: ...If water has been smeared on electric charge part use it after removing water Donʼt let metallic products of necklace coin key watch etc touch the battery terminal Or else it may cause fire hazard and product deformation Or else it may cause product failure Or else it may cause product failure and injury WHEN USING Wax Thinner ...

Page 6: ...ly 220 240V AC 50 60HZ 1Ø Dimension 200mm W X 120mm H X 55mm D Connectable Units 1 Outdoor Unit per Electric Power Distribution Indicator Count Method for Electric Power Distribution Power Consumption of each Indoor Unit Power Consumption of Outdoor Unit x Weighting Power of each Indoor Unit Weighting Power of total Indoor Units Weighting Power of each Indoor Unit Operation On Off x Capacity of In...

Page 7: ... Button 6 SHIFT Button for LCD Screen Change Available Watt hour meter Local purchase 1 2 3 4 5 6 ENGLISH Parts of a PDI Use the digital watt meter which send the pulse signal depending on the power consumption Use watt meter of 1W pulse 2W pulse 4W pulse 6W pulse 8W pulse or 10W pulse or PT CT Type pulse width 40 400 msec ...

Page 8: ...unit OUT FAN A OUT FAN B Internet A Internet B 1Ø 220VAC Address setup Start End 00 03 Pulse type PDI 1Ø 220VAC MultiV MultiV PLUS Outdoor unit Indoor unit address setup 00 01 02 03 Watt meter 3Ø 380VAC or 1Ø 220VAC PI 485 Independent operation of PDI Connect the product as shown in the below connection diagram 1 MultiV MultiV PLUS 2 Multi V PLUS2 or 3 series Wiring Diagram ...

Page 9: ... End 00 03 Pulse type PDI 1Ø 220VAC MPS multi Outdoor unit Indoor unit address setup 00 01 02 03 PI 485 Watt meter 3Ø 380VAC or 1Ø 220VAC 3 MPS multi Product NOTE In connecting Multi product PI 485 must be connected for PDI PI 485 must be purchased separately ...

Page 10: ...or unit address setup PI 485 PI 485 Watt meter Slave Setting Slave Setting Watt meter 3Ø 380VAC or 1Ø 220VAC 00 01 02 03 7C 7D 7E 7F ACP ACSMART Or LAN LAN LA LAN LAN LAN LAN AN LAN A A A A LAN LAN LAN N LA LAN LAN A AN N LAN LA LAN L LA A LAN LA LAN L LAN AN N LA AN N N N L LA AN N N N L LAN LA A A AN N L L LA A A AN N AN L LA L L L L LA NOTE Multi V PLUS 2 or 3series Product does not need PI485 ...

Page 11: ... RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO 1 2 3 4 Web PDI LG NET 1 MENU SELECT TX RX LG NET 2 TX RX LG NET 3 TX RX LG NET 4 TX RX Ethernet 1 ACT LNK Ethernet 2 ACT LNK Console Run Power TX RX FDD TX RX Ext TX RX DI 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DO ...

Page 12: ... B WHM PDI Multi V PI 485 Indoor unit The color and polarity of the communications line can differ from what s indicated on the PCB depending on the manufacturer of watt meter Black white Turn on the power after connecting the product Install the product as per the following wiring diagram Internal Wiring Diagram Internal Wiring Diagram 12 Electricity Distribution Indicator ...

Page 13: ...set the product 00 Unit When using in connection with indoor communication Line Of MultiV MultiV PLUS 10 Slave when using in connection with central controller 11 Master when not using in connection with central controller Ex Product selection Master Watt meter 1W 1 pulse 1 1 0 0 0 0 0 0 0 M a s t e r 1 W p M I C R O N I C N O S T B P 11 Independent operation of PDI Option setup screen Initial Scr...

Page 14: ...e reading service ID When two digits flash use the or key to select the remote reading service company 1 1 0 0 0 0 0 0 0 M a s t e r 1 W p M I C R O N I C N O S T B P 000 MICRONICS 001 LSIS COM 010 CI TOPIA 011 OMNI SYS 100 LG ACP for WEB PDI 000 Installation After setting the product press to select the next option LGAP Press the key to set up the Option for remote reading service company selecti...

Page 15: ...the watt hour meter 1 1 0 0 0 0 0 1 0 M a s t e r 2 W p M I C R O N I C N O S T B P 000 1 wh Pluse 001 2 wh Pluse 010 4 wh Pluse 011 6 wh Pluse 100 8 wh Pluse 101 10 wh Pluse 110 PT CT In case of CT using After setting value of CT watt hour meter press SHIFT key I n p u t I n P u l s e k W h C T 0 0 0 2 0 P r 0 2 5 0 0 After setting PT CT 110 press SHIFT key 1 1 0 0 0 1 1 0 0 M a s t e r PT CT M I...

Page 16: ...ndby power indication selection When the forth digit flashes use the or key to select the standby power 0 NO STBP Does not show the standby power 1 CAL STEP Shows the standby power Note If the PDI has been set Slave in previous option selection then Certainly Set NO STBP Ex Product selection Master standby power indication selection 1 1 0 0 0 0 0 0 1 M a s t e r 1 W p M I C R O N I C C A L S T B P...

Page 17: ... marcket Domestic So skip this setting in the procedure for overseas marcket Press the SHIFT key When the first two digits flash use the s or t key to select the remote reading service ID by company 4 After entering the remote reading service ID press the Shift key to enter the indoor address selection mode In case of the selecting Master Slave OMNI SYS ID setup OUT DR ID CITOPIA XX CI TOPIA ID se...

Page 18: ...ve is selected You can distribute the using power to maximum of 64 indoor units When showing the stand by power maximum of 63 indoor units Installation If the PDI connects to 64 indoor units set the addresses of indoor units from 00 to 3F Central control address 00 3F Ex If addresses of indoor units are set by 12 13 14 and 15 set start address by 12 and set end address by 15 Press the Menu key to ...

Page 19: ... products Except CRUN products or Multi Non Inverter Product applied Common PCB Refer to NOTE or Multi Inverter Product Central Controller All types Without LGAP 1 and 4 ON All others OFF Multi V products Except CRUN products or Multi Non Inverter Product applied Common PCB or Multi Inverter Product Central Controller All types Using LGAP 2 ON All others OFF Multi Non Inverter Product Centroller A...

Page 20: ... Clr 3 Press the Program Setup Clr keys at the same time for 3 seconds to set up the indoor address The room address on the PDI is listed in the ascending order of indoor number Ex If the indoor addresses are 7C 7D 7E and 7F the order of the indoor unit on the PDI are 1 2 3 and 4 The indoor numbers must be entered in sequence to be accurately recognized in the PDI Ex Correct indoor unit address se...

Page 21: ...settings mode After setup it automatically gets out of setup mode if there is no button input for 25 seconds When exiting without pressing set button the manipulated value is not reflected 7 If entering into address setup mode by using button it indicates as picture below 2 If pressing button long for 3 seconds it enters into remote controller setter setup mode If pressing once shortly it enters i...

Page 22: ...de until timer segment display 01 01 1 Set Group No by pressing button 3 Move to Indoor No setting option by pressing button 4 Set Indoor No by pressing button 5 Press button to save or release 6 Press button to exit or system will automatically exit after 25 seconds without any input 7 Repeat pressing button to select Function code 02 Ex Setting Address as F5 2 ...

Page 23: ... remote controller and use it 3 A No use For Power Distribution Indicator Used for Central Control settings 2 Address check mode 1 With the top right key pressed press the Reset button Press the left key for more than 3 seconds 2 Press the On Off key once directing the remote controller to the indoor unit The indoor unit shows the setting address and the address setup is completed The time and met...

Page 24: ...up Address No and Indoor unit Address No 00 FF 2 When you press the START STOP button on your remote controller directed toward the receiver of indoor unit after setting address the address would be set 3 When you press RESET button after completing address setup the address setup function will be cancelled In the state of cancellation LCD display shows the initial standby mode 4 You are recommend...

Page 25: ...he address display time and method can differ by the indoor unit type 2 Reset the remote controller to use the general operation mode 3 By using the TEMPERATURE SETTING button set the indoor unit address Setting range 00 FF 2 After setting the address press the ON OFF button toward the indoor unit 1 time 3 The indoor unit will display the set address to complete the address setting The address dis...

Page 26: ...HM should be installed in the specified cabinet which can protect the Power Distribution Indicator from water and humidity NOTE WHM Watt hour meter Suppl power after completing the Wiring Set the Power Distribution Indicator so as to fit the usage condition Installation Guide EX1 EX2 EX3 EX4 ...

Page 27: ... PWR Distribution Display Mode Accumulated PWR Display Mode Period Accumulated PWR Display Mode Initial Mode Press Menu key Press Shift key Indoor 1 Value LGAP P W R X X X X X X X X X X X X X X D i s t 0 1 X X X X X Total SUM Value P W R X X X X X X X X X X X X X X D i s t 0 2 X X X X X Total SUM Value Indoor 2 Value Indoor 3 Value Indoor 4 Value LGAP It displays the current power consumption of e...

Page 28: ...oor unit Kwh When 1 2 indoor units are connected only 1 page is displayed When 4 or more indoor units are connected press the Shift key to check the next page Press Shift key Indoor 1 Value A C C X X X X X X X X X X X X X X X X P W R 0 1 X X X X X X Total SUM Value A C C X X X X X X X X X X X X X X X P W R 0 2 X X X X X X Total SUM Value Indoor 2 Value P W R S T B P 0 0 0 0 0 D i s t 0 0 0 0 0 0 0...

Page 29: ...o clear the data As the function for manual check when cleared after the check it displays the cumulated power from the clearing point When classifying the stand by power it is shown after the last page Press Shift key Indoor 1 Value P e r i d X X X X X X X X X X X X X X A C C M 0 1 X X X X X Total SUM Value P e r i d X X X X X X X X X X X X X X X A C C M 0 2 X X X X X Total SUM Value Indoor 2 Val...

Page 30: ...30 Electricity Distribution Indicator ...

Page 31: ......