CAUTION
When installing the wired remote controller, do not bury it in the wall.
(It can cause damage in the temperature sensor.)
Do not install the cable to be 50m or above.
(It can cause communication error.)
• When installing the extension cable, check the connecting direction of the connector of the remote
controller side and the product side for correct installation.
• If you install the extension cable in the opposite direction, the connector will not be connected.
• Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above.
Remote Controller Installation
Wall
Side
Wall
Side
Wall
Side
Wall
Side
<Connecting order>
<Separating order>
3. Please fix remote controller upper part into the setup board
attached to the surface of the wall, as the picture below, and
then, connect with setup board by pressing lower part.
- Please connect not to make a gap at the remote controller and
setup board’s upper and lower, right and left part.
- Before assembly with the installation board, arrange the Cable
not to interfere with circuit parts.
When separating remote controller from setup board, as the
picture below, after inserting into the lower separating hole
using screw driver and then, spinning clockwise, remote
controller is separated.
- There are two separating holes. Please individually separate one
at a time.
- Please be careful not to damage the inside
components when separating.
4. Please connect indoor unit and remote controller using connection cable.
5. Please use extension cable if the distance between wired remote controller and indoor unit is more
than 10m.
Please check if connector is normally connected.
Connecting cable
Indoor
Unit side
12V
Red
Signal
Yellow
GND
Black
1,MFL67855401,영영 2017. 6. 29. 영영 1:50 Page 26