41
ERROR
ERROR DECISION
BASIS
CAUSE FOR ERROR
OCCURRENCE
REMEDY
PRESSURE
SENSOR
OVER
FLOW
ERROR
MOTOR
ERROR
LID
LOCK
ERROR
·
Pressure switch has a
bad connection or the
switch has failed.
·
Check the connections at the
pressure switch and at the
BLUE 6-pin connector at the
main board.
·
Check the pressure sensor
(21~23Ω ±10%) and
connection
·
Check the valves to be sure
there is no input leakage. Then
check the drain hose and make
sure the drain pipe is between
0.9 ~ 1.2 m (36 and 48 inches)
above the floor.
·
Check for blockages and leaks
in the air hose between the tub
and the pressure switch.
·
Check and repair any air
leakages at the air hose
connector on the outer tub and
at any connecting parts.
·
Check the connections at the hall
sensor and at the BLUE
6-pin connector on the main board.
·
Check the connections at the
stator and at the yellow 3-pin or
BLUE 6-pin connector on the
main board. Test the stator to
determine it is not defective.
·
Test hall sensor to determine it
is not defective.
·
Turn the drum to verify the
bearings are not locked.
·
Check the lid lock SW trying
locking
·
Check the balance of the lid
·
Reseat the connector.
·
Replace the switch.
·
Install the drain hose between
0.9 ~ 1.2 m (36 and 48 inches)
above the floor.
·
Replace pressure sensor
switch
·
Remove the foreign objects
in pressure sensor switch
air hose.
·
Replace the stator if necessary.
·
Replace the hall sensor if
necessary.
·
Replace the bearings if
necessary.
·
If trying, replace the Lid lock
SW or not trying replace the
Main PCB
·
Replace the lid or se the
balance
Summary of Contents for TS1301DPS
Page 17: ...17 ...
Page 18: ...18 3 4 WASHING PROGRAMS ...
Page 19: ...19 ...
Page 20: ...20 ...
Page 21: ...21 ...
Page 22: ...22 ...
Page 23: ...23 Course Pre washNormal ...
Page 24: ...24 ...
Page 25: ...25 ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 29: ...29 ...
Page 30: ...30 ...
Page 52: ...52 5 EXPLODED VIEW TOP COVER ASSEMBLY CABINET ASSEMBLY TUB ASSEMBLY ...
Page 56: ...July 2013 PRINTED IN CHINA ...