Installation of Outdoor Unit
Installation Manual
13
ENGLISH
• If making a hole to the wall is required to con-
nect pipe between the indoor unit and the out-
door unit, please follow below descriptions.
- Drill the piping hole with a ø70mm hole core
drill.
- Piping hole should be slightly slant to the
outdoor side to prevent raindrop into indoor
side.
Wall
5~7mm
Indoor
Outdoor
Drill a Hole in the Wall
For controlling the heating according to the external temperature, it is necessary to install the exter-
nal temperature sensor.
The sensor must be set up in a shady spot.
The sensor must not be set up above a window or door. It must be located away from heat
sources.
For measuring external temperature, the sensor type PT 1000 is used.
T
Temperature sensor for external temperature.
The external sensor must be connected and watertight to prevent water penetration.
Set up and connection of the external sensor
Temperature sensor for external temperature.
The direction of connecting cables.