Accessories Installation
Installation Manual
63
ENGLISH
ʶ
ʹ
ʸ
ʶ
ʺ
Terminal
Block 3
Terminal
Block 1
ʸ
ʶ
ʶ
ʷ
ʹ
ʺ
Terminal
Block 1
Terminal
Block 3
Relay contactor
port no. assignment
ELB(MCCB) port no.
assignment
1
3
2
4
How to Install Sanitary Water Tank Kit
Fellow bellow procedures Spet 1 ~ Step 5
Step 1.
Find magnetic switch and ELB(MCCB) in the kit. Fit
them into the indoor unit control box with enclosed a
braket and screws.(symbol
Ⓐ
at picture)
Step 2.
Contact ‘CN_B/HEAT(A)’(white connector)of the indoor
unit PCB with magnetic switch contact using encolsed
cable(symbol
Ⓑ
at the picture). Connect magnetic
switch contactor port no. A1 and A2.
Step 3.
Connect magnetic switch contactor port no.L1 and L3
with RLB(MCCB) port no. 2 and 4(symbol
Ⓒ
at the pic-
ture).
Check Poarity
• Connect magnetic switch contact port no. L1 to ELB(MCCB)
port no.2
• Connect magnetic switch contact port no. L3 to ELB(MCCB)
port no.4
Step 4.
Connect magnetic switch contactor port no. T1 and T3
with terminal block 1 port 6 and 7(symbol
Ⓓ
at the pic-
ture).
Check Polarity
• Connect magnetic switch contact port no. T1 to terminal
block 1 port 6
• Connect magnetic switch contact port no. T3 to terminal
block 1 port 7
Step 5.
1Ø Electric Heater
’
Connect ELB(MCCB) port no.1 and 3 with block 3
port 3 and 4(symbol
Ⓔ
at the picture).
’
Connect ELB(MCCB) port no.1 and 3 with block 3
port 1 and 2(symbol
Ⓔ
at the picture).
Check Polarity
- Connect ELB port no. 1 to terminal block 3 port 3
- Connect ELB port no. 3 to terminal block 3 port 4
- Connect MCCB port no. 1 to terminal block 3 port 1
- Connect MCCB port no. 3 to terminal block 3 port 2
CAUTION
Note
:
Some models are using MCCB instead of ELB
3ø Electric Heater
1ø Electric Heater
Summary of Contents for Therma V AHUW096A2
Page 97: ......