COMPONENT TEST
5. Touch the ohmmeter test leads to limiter terminals
1A and 2A. The meter should indicate
continuity(0
Ω
)
6. Touch the ohmmeter test leads to limiter
terminals 1B and 2B.
With the temperature below (150˚F/65.5˚C), the
meter should indicate an open circuit(infinite).
With the temperature above (150˚F/65.5˚C), the
meter should indicate continuity (0
Ω
).
Bridge surface units:
Left Front(LF),
Left Center(LM)
and
Left Rear(LR)
Element
Components
Test procedures
Results
Normal: continuity
(below 0.5
Ω
)
If not replace
Normal: continuity
(below 0.5
Ω
)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0
Ω
)
If not replace
<Normal>
Below (150˚F/65.5˚C)
open circuit (infinite).
Above (150˚F/65.5˚C)
continuity (0
Ω
)
If not replace
LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes