COMPONENT TEST
Bridge surface units:
Left Front(LF),
Left Center(LM)
and
Left Rear(LR)
Element
1. Refer to page 3-4 for the servicing procedure
2. Set the Multiple meter scale to the R x 1
3. Disconnect wires from cook-top elements
4. Touch the ohmmeter test leads to the element
terminal and 1A.
The meter should indicate.
- (E1 & E2)
32.0
Ω
± 10%
- (E3 & E4)
72.0
Ω
± 10%
- (E5 & E6)
32.0
Ω
± 10%
Components
Test procedures
Results
Normal: Approximately 32
Ω
,
If not replace
Normal: Approximately 72
Ω
,
If not replace
Normal: Approximately 32
Ω
,
If not replace
LGE Internal Use Only
Copyright © 2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes