63
Installation
Installation of unit
6RWU0-03A
PTAC
PREFERRED METHOD
Ensure proper ground
exists before use
Use Wall Receptacle
Power Supply
Standard 208/230V, 3-wire
grounding receptacle rated 15A
Standard 208/230V, 3-wire
grounding receptacle rated 20A
Use 15 AMP. time
delay fuse or 15 AMP.
Circuit breaker.
Use 20 AMP. time
delay fuse or 20 AMP.
Circuit breaker.
(2500W Heater
ơ
15Amp
Circuit Breaker)
(2000W Heater
ơ
15Amp
Circuit Breaker)
Use 30 AMP. time
delay fuse or 30 AMP.
Circuit breaker.
Standard 208/230V, 3-wire
grounding receptacle rated 30A
Use 20AMP,time delay
fuse or 20AMP
Circuit breaker
Standard 265V grounding
receptacle rated 20A
Use 25AMP,time delay
fuse or 25AMP
Circuit breaker
Standard 265V grounding
receptacle rated 25A
Use 30AMP, time delay
fuse or 30AMP
Circuit breaker
Standard 265V grounding
receptacle rated 30A
CAUTION
1. Do not use an extension cord with this unit.
2. When the unit is in the OFF position, the power supply to the electri-
cal controls is still energized.
3. Disconnect the power to the unit before servicing
the unit.
4. Remove the power cord from the wall receptacle.
5. Remove or turn off the protective device (fuses or circuit breaker).
Wirings including installation of the receptacle must comply with the
NEC and local codes, local regulations.
FUSE
- Use a time-delay fuse or circuit breaker. Refer to the nameplate
for proper power supply requirements.
ELECTRICAL SAFETY
IMPORTANT
(PLEASE READ CAREFULLY)
FOR THE USER'S PERSONAL SAFETY, THIS APPLI-
ANCE MUST BE PROPERLY GROUNDED
The power cord of this appliance is equipped with a three-
prong (grounding) plug. Use this with a standard three-slot
(grounding) wall power outlet to minimize the hazard of elec-
tric shock. The customer should have the wall receptacle and
circuit checked by a qualified electrician to make sure the
receptacle is properly grounded.
DO NOT CUT OR REMOVE THE THIRD (GROUND)
PRONG FROM THE POWER PLUG.
Installation(for 60Hz)
• Electric installation requirement for personal safety:
• This equipment must be properly connected to ground.
• Under no circumstances cut or break the grounder conductor.
• We recommend not to use an extension wire or any adaptor with this product.
• Follow the national or local electric codes.
• If the power supply does not fulfill the specifications previously mentioned, call an authorized electrician.
• The aluminum wired in the houses may bring about some problems, call an authorized electrician.
• This unit requires a separated power supply that works only for this application.
FUSE –
Use a time – delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.