43 Product Data
YA Chassis
PTAC
6RWU0-03A
1.8 Electrical characteristics
Unit
Power
Compressor
Motor FLA
Model
Hz
Voltage Voltage range
MCA
MOP
RLA
LRA
IFM
OFM
UYC073ALE21(LP073CD2B)
60
208~230
Min : 187
Max : 253
14.9
15.0
2.9
16.0
0.36
0.36
UYC093ALE31(LP093CD3B)
19.5
20.0
3.7
19.0
0.36
0.36
UYC123ALE31(LP123CD3B)
19.5
20.0
5.0
27.0
0.36
0.36
UYC153ALE31(LP153CD3B)
19.5
20.0
6.55
38.6
0.36
0.36
UYH073ALE21(LP073HD2B)
14.9
15.0
2.9
16.0
0.36
0.36
UYH093ALE31(LP093HD3B)
19.5
20.0
4.0
19.0
0.36
0.36
UYH123ALE31(LP123HD3B)
19.5
20.0
5.0
26.0
0.36
0.36
UYH153ALE31(LP153HD3B)
19.5
20.0
6.55
38.6
0.36
0.36
UYC09EALE31(LP096CD3B)
265
Min : 239
Max : 292
17.9
15.0
3.3
20.0
0.36
0.36
UYC12EALE31(LP126CD3B)
17.9
15.0
4.4
22.0
0.36
0.36
UYH09EALE31(LP096HD3B)
17.9
15.0
3.3
20.0
0.36
0.36
UYH12EALE31(LP126HD3B)
17.9
15.0
4.4
22.0
0.36
0.36
Notes :
1. Voltage range Voltage supplied to the unit terminals should be
within the minimum and maximum range.
2. Maximum allowable voltage unbalance between phase is 2 %.
3. Select wire spec. based on the larger value of MCA.
4. LRA & RLA is measured during each individual compressor test
condition.
5. IFM & OFM is measured at unit test condition.
6. Recommended circuit breaker is ELCB (Earth Leakage circuit
breaker)
MCA : Minimum Circuit Amperes (A)
MOP : Maximum rating over current protective device (A)
LRA : LRA Locked Rotor Ampere (A)
RLA : Rated Load Amperes (A)
OFM : Outdoor Fan Motor (W)
IFM : Indoor Fan Motor (W)
FLA : Full Load Amperes (A)