7
Troubleshooting and inspection direction
-27-
Not able to set product function with a remote control.
Does an alarm occur when
you operate the keys on the
remote control?
Is the power of CN-REC 1&2 DC+5V?
Replace MAIN PCB ASM.
YES
YES
NO
NO
• Check batteries of remote controller.
Plasma dust collector malfunction
Is MICOM SWITCH connected properly?
Is the power of CN-HVB
(CONNECTOR) PIN 1&3 12V?
Is High voltage on both
terminals of HVB ASSY present?
Replace Plasma Filter ASSEMBLY.
YES
YES
YES
NO
NO
NO
• Replace MICOM SWITCH.
• Replace MAIN PCB.
• Replace HVB ASSY.
• Check MAIN PCB ASM CN-REC
connection