21
INSTALLATION
EN
G
LI
SH
a
Pressure regulator
Connecting Electricity
Electrical Requirements
This appliance must be installed and grounded on
a branch circuit by a qualified technician in
accordance with the National Electrical code ANSI/
NFPA NO. 70 - latest edition.
All wiring should conform to Local and NEC codes.
This range requires a single-phase, 3 wire, AC 120/
208 V or 120/240 V 60 Hz electrical system. Use
only a 3-conductor or a 4-conductor UL - listed
range cord with closed-loop terminals, open-end
spade lugs with upturned ends or similar
termination. Do not install the power cord without
a strain relief.
A range cord rated at 40 amps with 120/240
minimum volt range is required. If a 50 amp range
cord is used, it should be marked for use with 13/
8" diameter connection openings. This appliance
may be connected by means of a conduit or power
cord. If a conduit is being used, refer to "3-Wire
Connection: Conduit" or "4-Wire Connection:
Conduit" sections.
WARNING
• Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the
line so that the range can be moved if servicing
is ever necessary.
• The power supply cord and plug should not be
modified. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
• Using an extension cord to connect the power is
prohibited. Connect the power cord and plug
directly.
• Electrical ground is required on this appliance.
• Make sure that the power cord is not pinched by
the range or heavy objects. Failure to do so can
result in serious burns or electrical shock.
NOTE
• If an external electrical source is utilized, the
appliance, when installed, must be electrically
grounded in accordance with local codes or, in
the absence of local codes, with the National
Electrical Code, NFPA70 or the Canadian Electric
Code, CSA C22.1-02.
Specified Power Cord Kit Rating
Case 1
• Voltage: 120/240 volts (3-wire)
• Range rating: 8,750 W - 16,500 W
• Specified rating of power supply-cord kit,
amperes: 40 A or 50 A
• Diameter (inches) of range connection opening
- Power cord: 1 3/8"
- Conduit: 1 1/8"
Case 2
• Voltage: 120/240 volts (3-wire)
• Range rating: 16,501 W - 22,500 W
• Specified rating of power supply-cord kit,
amperes: 50 A
• Diameter (inches) of range connection opening
- Power cord: 1 3/4"
- Conduit: 1 3/8"
Case 3
• Voltage: 120/208 volts (3-wire)
• Range rating: 7,801 W- 12,500 W
• Specified rating of power supply-cord kit,
amperes: 40 A or 50 A
• Diameter (inches) of range connection opening
- Power cord: 1 3/8"
- Conduit: 1 1/8"
Case 4
• Voltage: 120/208 volts (3-wire)
• Range rating: 12,501 W - 18,500 W
• Specified rating of power supply-cord kit,
amperes: 50 A
• Diameter (inches) of range connection opening
- Power cord: 1 3/4"
- Conduit: 1 3/8"
3, 4 - Wire Electrical Wall Receptacle
4 Wire receptacle (14-50R)
3 Wire receptacle (10-50R)
us_main.book.book Page 21 Thursday, January 27, 2022 1:33 PM
Summary of Contents for PrintProof LSDL6336 Series
Page 1: ...항목 Spec 재질 모조지 평량 80 사이즈 B5 표지 여부 유 페이지 수 180 인쇄 도수 1도 ...
Page 85: ...83 Memo us_main book book Page 83 Thursday January 27 2022 1 33 PM ...
Page 86: ...84 Memo us_main book book Page 84 Thursday January 27 2022 1 33 PM ...
Page 177: ...91 Memorándum ls_main book book Page 91 Thursday January 27 2022 1 47 PM ...
Page 178: ...92 Memorándum ls_main book book Page 92 Thursday January 27 2022 1 47 PM ...
Page 179: ...93 Memorándum ls_main book book Page 93 Thursday January 27 2022 1 47 PM ...
Page 180: ...94 Memorándum ls_main book book Page 94 Thursday January 27 2022 1 47 PM ...
Page 181: ...95 Memorándum ls_main book book Page 95 Thursday January 27 2022 1 47 PM ...